5 Status Indicators
5.1 ACTpro-1500
Status indicators appear on the front of the ACTpro-1500 Door Controller.
The meaning of each indicator is described below.
(A) Power / System Running
This indicates that the ACTpro Controller has power.
(B) Communications
Constant illumination indicates that all enabled door stations are online.
Flashing indicates that one or more door stations are offline.
(C) Fault
Illuminates to indicate a fault on the system.
Possible causes are:
l
Tamper open: ACTpro Controller housing is not closed.
l
Break Glass: ACTpro Controllers provide a method to monitor an Emergency break glass switch via the
B/GL input. The fault LED will illuminate if the Emergency break glass switch is activated.
l
Mains Fault: ACTpro-1500 Controller will accept a mains present signal from a PSU (pre-wired on
ACTpro-1500). This is wired into MAINS PRESENT input on the PCB. When the PSU has no mains
supply the fault is active.
l
Door Station offline: When one or more enabled door stations are not communicating with the ACTpro
Controller the Fault LED illuminates and the appropriate network green LED on the PCB will flash.
l
Low Supply Voltage: When voltage to the +12V terminal is less than +9V.
l
Fuse Blown: The +12V output on the READER terminals is current limited to provide short circuit
protection. The Fault LED will illuminate if too much current is drawn from this connection.
5.2 ACTpro-15002A and ACTpro-1500PoE
Fault indication
Mains present
© Vanderbilt 2019
17