2.2.1 Mounting
1. Mount securely in correct orientation allowing minimum clearance – see diagram.
2. Route mains and low voltage output cables via different knockouts and/or cable entry holes.
3. Use bushes and cable glands rated to UL94 HB minimum.
2.2.2 Mains power up
1. Attach correctly rated mains cable (minimum 0.5mm
2
[3A], 300/500V AC) and fasten using cable
ties.
2. Apply mains power and:
l
Check for 13.8V DC on load outputs.
l
Check green Mains LED is on.
3. Disconnect mains power.
2.2.3 Load Output
1. Attach correctly rated load cable and fasten using cable ties. Note polarity.
2. Apply mains power and check green Mains LED is on.
Note:
Red LED may be illuminated (dependent upon model) to indicate that no battery has been
connected. This is normal.
3. Verify load is operating correctly.
4. Disconnect mains power.
2.2.4 Standby Battery
Note:
Ensure batteries being fitted to this unit are in good condition
1. Connect battery leads to battery, ensuring correct polarity of battery connections. Vanderbilt
recommend using a 7Ah battery.
2. Apply mains power and check that the green Mains LED is on.
3. Check there is no fault indication on Red LED (dependent on model).
4. Disconnect mains power.
5. Check that the batteries continue to supply voltage and current to the load.
The Green LED should be off.
ACTpro-1500/-15002A/-1500PoE Door Controller – Installation and Operating Instructions
Installation
© Vanderbilt 2019
8
A-100535-c
15.03.2019