Wire Colour
Terminal
Orange
(Buzzer Control)
2.1.3 Wiring exit readers
For Clock & Data readers, wire exit reader in parallel but leave the sense line unconnected.
For Wiegand readers, wire the DATA 0 of the exit reader to SENSE on the ACTpro-100.
Max length 30m with 5V DC
Max length 100m with 12V DC
Cable: 8 Core Screened Belden 9504 or equivalent
2.2 ACTpro-100
2.2.1 Mounting
Mount the ACTpro door station directly on to the wall with the supplied screws.
The keyed mounting hole should be screwed first to the wall to aid the mounting.
The unit should be installed in a ventilated area that allows for accessibility after installation.
2.2.2 Power supply
The ACTpro-100 requires an external 12V DC power supply. The supply should be connected to the +12V
DC and 0V/GND connections.
2.3 ACTpro-1002A
This unit is only suitable for installation as permanently connected equipment.
l
The PSU is not suitable for external installation.
l
Equipment must be earthed.
Before installation, ensure that external disconnect device is OFF. The PSU should be installed via a 3A
fused spur according to all relevant safety regulations applicable to the application.
ACTpro-100 / ACTpro-1002A – Installation and Operating Instructions
Installation
© Vanderbilt 2018
9
A-100542
05.11.2018