ACTpro-100 / ACTpro-1002A
Installation and Operating Instructions
Document ID: A-100542
Edition date: 05.11.2018
Page 1: ...ACTpro 100 ACTpro 1002A Installation and Operating Instructions Document ID A 100542 Edition date 05 11 2018 ...
Page 2: ...hat this equipment type is in compliance with the following EU Directives for CE marking Directive 2014 30 EU Electromagnetic Compatibility Directive Directive 2011 65 EU Restriction of the use of certain hazardous substances Directive The full text of the EU declaration of conformity is available at http van fyi Link DoC ACTpro 1002A Hereby Vanderbilt International IRL Ltd declares that this equi...
Page 3: ...ion 6 2 1 Wiring 6 2 1 1 DIP switch addressing 7 2 1 2 Wiring for Vanderbilt EM1030e Clock Data or Wiegand Reader 8 2 1 3 Wiring exit readers 9 2 2 ACTpro 100 9 2 2 1 Mounting 9 2 2 2 Power supply 9 2 3 ACTpro 1002A 9 2 3 1 Mounting 10 2 3 2 Mains power up 10 2 3 3 Load Output 10 2 3 4 Standby Battery 11 2 3 5 Tamper 11 Vanderbilt 2018 3 A 100542 05 11 2018 ...
Page 4: ... to 50 C 10 to 40 C 75 RH non condensing Dimensions H x W x D mm 165 x 235 x 55 275 x 330 x 80 Weight kg 0 4 2 2 Enclosure Material ABS 1 2mm steel grey powder coated LED Status Indicators Yes Yes PSU Fault Output n a Yes Lid Opening Tamper Detection Front Yes Yes Rear Tamper Detection No Yes 1 1 1 ACTpro 1002A electrical specification Battery charging Yes Standby Battery 12V 7Ah Battery Battery D...
Page 5: ...on ACTpro 1002A V54502 C121 A100 Single door station with 12V DC 2A PSU 1 3 Monitoring All faults including Mains Present and Tamper are reported on the ACT Enterprise software Mains present The PSU MAINS PRESENT output when available is pre wired to the MAINS PRESENT input Output Voltage The PSU output voltage level is reported to the ACT Enterprise software Tamper The enclosure lid is tamper mon...
Page 6: ... to the controller is disconnected during installation Mains power should be connected by a licensed electrician in accordance with local national codes 2 1 Wiring A Door contact F Vanderbilt reader wire colour coding B Door push button G Important Always place varistor across lock terminals C From previous door or controller H Double pole Break Glass Emergency Door Release When the Break Glass is...
Page 7: ...e linked to 0V or the feature should be disabled in ACT Enterprise software l The Blue Comms OK LED is on while ACTpro 100 is communicating with the controller l Red Fault LED illuminates on l Tamper l Comms Offline l BreakGlass l Voltage Low l Current Limiting Fuse 500mA 2 1 1 DIP switch addressing Door 1 is on the ACTpro 1500 controller max 31 doors Door 1 and 2 is on the ACTpro 4000 controller ...
Page 8: ... 2 1 2 Wiring for Vanderbilt EM1030e Clock Data or Wiegand Reader Wire Colour Terminal White SENSE Green CLOCK DATA 1 Blue DATA DATA 0 Red 12V Black 0V Brown RED Yellow GREEN ACTpro 100 ACTpro 1002A Installation and Operating Instructions Installation Vanderbilt 2018 8 A 100542 05 11 2018 ...
Page 9: ...nting The unit should be installed in a ventilated area that allows for accessibility after installation 2 2 2 Power supply The ACTpro 100 requires an external 12V DC power supply The supply should be connected to the 12V DC and 0V GND connections 2 3 ACTpro 1002A This unit is only suitable for installation as permanently connected equipment l The PSU is not suitable for external installation l Eq...
Page 10: ...bilt recommend that you place the provided ferrite bead a noise suppression device around the power supply cable to attain a desired level of electromagnetic compatibility EMC The ferrite bead is provided along with a screw kit in a clear ziplock bag inside the unit enclosure 2 Apply mains power and l Check for 13 8V DC on load outputs l Check the green Mains LED is on 3 Disconnect mains power 2 3...
Page 11: ...he batteries continue to supply voltage and current to the load The green Mains LED should be off Note Batteries must have sufficient charge to supply the load 5 Reconnect mains power The green Mains LED should be on 6 Remove Load fuse and check that the red Fault LED is on dependent on model 2 3 5 Tamper A tamper condition is reported in software 1 Check that the tamper switch is reported in the ...