1 Overview
This guide describes the installation of the ACT365-ACU controller.
The ACT365-ACU Controller is a single door IP controller that requires an external 12V or 24V power
supply.
The ACT365-ACU2A Controller is a single door IP controller with a 12V DC 2A PSU.
The ACT365-ACUPoE Controller is a single door IP controller that is powered over Ethernet.
Sign up to ACT365 via www.act365.eu.
1.1 Technical specification
ACT365-ACU
ACT365-ACU2A
ACT365-ACUPoE
Voltage Range (Controller)
11–24V DC
11–24V DC
11–24V DC
Current Consumption
(Controller)
350mA (Max)
350mA (Max)
350mA (Max)
Controller Dimensions
(H x W x D mm)
165 x 235 x 55
275 x 330 x 80
275 x 330 x 80
Controller Weight (kg)
0.4
2.2
2.2
Operating Temperature
-10 to +50° C
-10 to +40° C
75% RH non-condensing
-10 to +40° C
75% RH non-condensing
Operating Environment
Surface
mounting
Internal use
only
Surface mounting
Internal use only
Surface mounting
Internal use only
Enclosure Material
ABS
1.2mm steel grey powder
coated
1.2mm steel grey powder
coated
LED Status Indicators
Yes
Yes
Yes
PSU Fault Output
n/a
Yes
Yes
Lid Opening Tamper Detection
(Front)
Yes
Yes
Yes
Rear Tamper Detection
No
Yes
Yes
1.1.1 Electrical specification
ACT365-ACU
ACT365-ACU2A
ACT365-ACUPoE
PoE 802.3bt input (PoE++)
N/A
N/A
13.8V at 3A 0.5A battery
charge
PoE 802.3at input (PoE+)
N/A
N/A
13.8V at 1A 0.5A battery
charge
© Vanderbilt 2019
4
A-100521-c
15.03.2019