
To interlock additional doors, continue linking OP3 and AUX I for each new door.
2. On the ACT365 customer portal, select the site from the site picker.
3. Under
Access Control > Doors
, for each interlock door:
a. Click the door name on the
Doors
screen.
b. Select the
Interlock
check box on the
Update Door
screen.
c. Click
Save
.
When
Interlock
is enabled on a door, the door is locked when the AUX input is active.
When the door is open, OP3 is active and pulls Aux I low (0V) on all interlock doors.
3.4 Intruder panel wiring
To arm/disarm an intruder panel:
1. Wire the intruder alarm panel to the controller as shown:
A
Intruder alarm panel
B
Connect the AUX Relay output from the controller to arm input on alarm panel. The AUX
Relay can be set to pulse or toggle. Toggle by programming the AUX Relay time to
zero.
C
Connect a signal from the alarm panel to indicate armed or disarmed status. If 0V is
connected to AUX Input, the panel is armed.
2. Wire the door from which the system will be armed/disarmed.
3. On the ACT365 customer portal, select the site from the site picker.
4. On the ACT365 customer portal, program the ACT365-ACU:
a. Click
Access Control > Doors >
<Door Name>
.
b. Under
Aux Relay
, select the
Arm Intruder Panel
check box.
c. Under
Operation
, select the
Intruder Panel
check box.
d. Click
Save
.
5. On the ACT365 customer portal, grant arm/disarm rights to users:
a. Click
Access Control > Cardholders >
<Card Holder Name>
.
b. Under
Options
, select the
Arm/Disarm
check box
c. Click
Save
.
6. To arm the system, a user with arm/disarm rights should press the tick key on the keypad then
present their card. Once the intruder panel is armed (as monitored by the AUX I PIN), the Door
ACT365-ACU / ACT365-ACU2A / ACT365-ACUPoE – Installation Instructions
Wiring
© Vanderbilt 2019
13
A-100521-c
15.03.2019