Vanair Start All Jump Pack Troubleshooting And Warranty Request Manual Download Page 5

MANUAL ACTIVATION FOR LOW VOLTAGE BATTERIES 

The 

Start•All Jump•Pack® 

is designed to jump-start 12VDC lead-acid batteries at very low voltage. If your battery is too low 

or unable to take a charge, the unit will display alternating red and green 8s. This is an indication that the 

Start•All 

ump•Pack®

 

 

Jump•Pack®

cannot detect a battery. If you need to jump-start a battery in this condition, turn on the headlights, blower, 

and/or 

another accessory. If the 

Start•All Jump•Pack®

still does not activate, there is a Manual Override feature, which allows you 

to force “On” the jumpstart function. 

CAUTION! USE THIS MODE WITH EXTREME CARE. THIS MODE IS FOR 12VDC LEAD-ACID BATTERIES ONLY. BOTH THE 

SPARK PROOF AND REVERSE POLARITY PROTECTION FEATURES ARE DISABLED. PAY VERY CLOSE ATTENTION TO THE 

POLARITY OF THE BATTERY BEFORE USING THIS MODE.  DO NOT ALLOW THE POSITIVE AND NEGATIVE BATTERY CLAMPS 

TO TOUCH OR CONNECT AS THE PRODUCT WILL GENERATE SPARKS. THIS MODE USES A VERY HIGH CURRENT (UP TO 

2500 AMPS) THAT CAN CAUSE SPARKS AND HIGH HEAT IF NOT USED PROPERLY. IF YOU ARE UNSURE ABOUT USING THIS 

MODE, DO NOT ATTEMPT AND SEEK PROFESSIONAL HELP. 

Before using the Manual Override feature, make sure the battery clamps are connected to the correct polarity battery 

terminals. To use the Manual Override feature, press and hold the “OUTPUT 12V” button for three (3) seconds. A solid 

Green 8 will indicate you have successfully entered Manual Override mode and are ready to jump-start your vehicle. 

d. If the 

Jump•Pack 

does not activate and display a green solid 8, return for servicing.

Click here for the Start-All Jump Pack Troubleshooting Video

IN0229 Rev.2 

8.

Jump•Pack

 shuts off during crank attempt or stops while cranking

a.

The E4 Error code displays

i.

Yes? Warm up the jump pack and try again.

ii.

No, see below

b.

Charge the 

Jump•Pack 

to full in accordance with section “Normal Charging Procedure for the

Start•All Jump•Pack® 

” and 

a

ttempt an engine start.

i.

The 

Jump•Pack

 persists in shutting off.

1.

Switch the power switch off and on again. Press the 

"o

utput

"

 button briefly.

2.

Read and 

r

ecord the percentage shown on the charge level display

a.

If display is below 65%, the battery may be damaged and may need

replacement.

9.

The 

Jump•Pack

 shows flashing red and green 8’s, but will not activate or show error codes

a.

Check the clamp connection to make sure it is connected to the battery and is free of paint, grease, dirt,

or corrosion.

b.

Make sure the vehicle ignition switch is turned to the 

"a

ccessory (ACC)

"

 position and that the headlights

or blower is turned on.

c.

If the above steps do not resolve the issue, 

u

se the 

"m

anual 

ac

ctivation mode

"

 as instructed below.