background image

1.

The

 Start•All Jump•Pack®

 does not turn on.

a.

Press the output button momentarily, then turn on the 

p

ower 

s

witch

i.

Does the 

Jump•Pack

 turn on?

ii.

If still off, proceed to step b.

b.

Plug in the charger

i.

Does the display turn on with a charge %?

1.

If the display turns on when plugged in, but then turns off when the 

Jump•Pack

 is

unplugged, check to see if the charge level is increasing by waiting 10 minutes. If it is not

increasing, measure the voltage. Put the positive probe of a voltmeter on the red clamp

and the negative probe on the metal housing of the cigarette lighter port.

a.

If it is not charging and is above 9.6V the battery is likely bad. Return the unit for

further testing to verify.

b.

If the voltage is below 9.6V the battery is possibly still good, the unit will still

need to be returned to manually recharge it.

2.

If the display does not turn on

a.

Check the charger for output. With the charger plugged in to an AC outlet but

not plugged in to the 

Jump•Pack

, measure with a voltmeter the inside with the

positive probe and the outside of the connector with the negative probe. It

should measure approximately 18 volts, if it does not, replace the charger.

b.

If the 

Jump•Pack

 display does not turn on and the charger is good, the jump

pack is defective and will need to be returned

2.

The 

Start•All Jump•Pack®

 and the display turns on, but it does not charge.

a.

Does the “IN” on the display flash when plugged in?

i.

No “IN” is not flashing.

1.

Check the charger for output. With the charger plugged in to an AC outlet but not

plugged in to the 

Jump•Pack

, measure with a voltmeter on the inside with the positive

probe and the outside of the connector with the negative probe. It should measure over

18 volts, if it does not, replace the charger. If it does measure over 18 volts, the control

board needs to be replaced; return unit for repair.

2.

If the 

Jump•Pack

 is 100% fully charged, the “IN” will stop flashing.

3.

If IN has stopped flashing but the display does not show 100%, go to “

r

ecalibrating the

display when the display will not reach 100%” procedure

ii.

The “IN” is flashing, but the battery charge level percentage will not increase, or will not reach

100%

1.

Go to “

r

ecalibrating the display when the display will not reach 100%”

2.

If the problem persists, Battery or control board is bad, return the unit.

3.

Strong arcing occurs when connecting the clamps to a battery

a.

Perform a check by attaching a clamp-on ammeter to one of the cables from the 

Jump•Pack

. Connect

the clamps to a known good 12V battery, ENSURE PROPER POLARITY

.

i.

With the 

Jump•Pack

turned off, there should be no current, if there is, the MOSFET board is bad

and the unit needs to be returned.

4.

Normal Charging Procedure for the 

Start•All Jump•Pack®

If Issues occur prior to cranking attempt 

IN0229 Rev.2 