background image

a.

With the 

Jump•Pack 

turned off, plug in either the AC charger or the 12V 

a

uxiliary 

p

ort charger into the

corresponding port.

i.

Check display.  If the display shows 0%, check the voltage per section 1.  If it is above 9.6 V,

proceed to step b.

ii.

If the voltage is below 9.6 V, the battery is damaged and the unit should be returned for service.

b.

Look for the “IN” to illuminate on the display,

i.

If working properly it will begin to flash

c.

Wait several minutes to observe the charge level percentage increase

d.

Continue to let the

 Jump•Pack

 charge 6-8 hours or until it automatically stops. The “IN” will stop flashing

and the charge level display will show 100%.

5.

Recalibrating the display when the display will not reach 100%

a.

Charge the jump per “Normal Charging Procedure for the S

tart•All Jump•Pack®.

b.

If it does not reach 100% when finished charging, then turn on the Jump Pack while it is still plugged in

 

to

the charger, and wait 15 seconds

.

c.

The display should recalibrate up to 100%

.

d.

If the display still does not show 100%, leave the S

tart•All

 on and turn the flashlight on or plug in an

accessory to slowly drain the battery. Drain the battery to 50% and recharge fully until IN stops flashing

--

--

Turn unit ON

.

e.

If the display still does not read 100%, measure the voltage of the clamps with a voltmeter. If the voltage

is above 16.4V, the battery is good.

NOTE: Many conditions affect the health of the battery, this includes age, the temperature it is stored at, how heavily it 

has been used, and other factors. These will degrade the battery over time and may affect the maximum charge % that 

will display. 

6. The clamps or cables are damaged

a. The clamps can be replaced with Vanair Part Number 14-450 Replacement Clamp Set

b. For cable damage, the unit can be returned for repair

If issue occurs during Cranking Attempt 

7.

The LED display shows an Error Code E

0

-E

9

a.

There is an error present. It could be any of the following

i.

E0: Low Jump Pack Battery Voltage Detected

1.

If the error appears when the Jump Pack is turned off and charging, then 1 or more cells in the Jump 

Pack battery is below a safe 2.4V minimum charge. This unit will not charge because of the potential 

unsafe condition. It will need to be returned for servicing.

2.

If the error ONLY appears when unit is powered on, then the charge level is below a safe % to jump 

start a vehicle or using the accessories without causing damage to the Jump Pack. It is possible to 

recharge the Jump Pack before using it when it is in this condition.

ii.

E1: Reverse polarity detected

1.

Check the clamps and ensure that the red clamp is connected to the positive post on the

 

battery and 

that the black clamp is connected to the negative post on the battery.

iii.

E2: Timed Out

1.

The 

Jump•Pack

 once connected to a battery and activated will stay engaged for 45

 

seconds. Switch 

off and back on the 

Jump•Pack

 to reset the timer.

IN0229 Rev.2 