3
a.
With the
Jump•Pack
turned off, plug in either the AC charger or the 12V
a
uxiliary
p
ort charger into the
corresponding port.
i.
Check display. If the display shows 0%, check the voltage per section 1. If it is above 9.6 V,
proceed to step b.
ii.
If the voltage is below 9.6 V, the battery is damaged and the unit should be returned for service.
b.
Look for the “IN” to illuminate on the display,
i.
If working properly it will begin to flash
c.
Wait several minutes to observe the charge level percentage increase
d.
Continue to let the
Jump•Pack
charge 6-8 hours or until it automatically stops. The “IN” will stop flashing
and the charge level display will show 100%.
5.
Recalibrating the display when the display will not reach 100%
a.
Charge the jump per “Normal Charging Procedure for the S
tart•All Jump•Pack®.
”
b.
If it does not reach 100% when finished charging, then turn on the Jump Pack while it is still plugged in
to
the charger, and wait 15 seconds
.
c.
The display should recalibrate up to 100%
.
d.
If the display still does not show 100%, leave the S
tart•All
on and turn the flashlight on or plug in an
accessory to slowly drain the battery. Drain the battery to 50% and recharge fully until IN stops flashing
--
--
Turn unit ON
.
e.
If the display still does not read 100%, measure the voltage of the clamps with a voltmeter. If the voltage
is above 16.4V, the battery is good.
NOTE: Many conditions affect the health of the battery, this includes age, the temperature it is stored at, how heavily it
has been used, and other factors. These will degrade the battery over time and may affect the maximum charge % that
will display.
6. The clamps or cables are damaged
a. The clamps can be replaced with Vanair Part Number 14-450 Replacement Clamp Set
b. For cable damage, the unit can be returned for repair
If issue occurs during Cranking Attempt
7.
The LED display shows an Error Code E
0
-E
9
a.
There is an error present. It could be any of the following
i.
E0: Low Jump Pack Battery Voltage Detected
1.
If the error appears when the Jump Pack is turned off and charging, then 1 or more cells in the Jump
Pack battery is below a safe 2.4V minimum charge. This unit will not charge because of the potential
unsafe condition. It will need to be returned for servicing.
2.
If the error ONLY appears when unit is powered on, then the charge level is below a safe % to jump
start a vehicle or using the accessories without causing damage to the Jump Pack. It is possible to
recharge the Jump Pack before using it when it is in this condition.
ii.
E1: Reverse polarity detected
1.
Check the clamps and ensure that the red clamp is connected to the positive post on the
battery and
that the black clamp is connected to the negative post on the battery.
iii.
E2: Timed Out
1.
The
Jump•Pack
once connected to a battery and activated will stay engaged for 45
seconds. Switch
off and back on the
Jump•Pack
to reset the timer.
IN0229 Rev.2