Van der Ende Groep · Aartsdijkweg 23, 2676 LE, Maasdijk · Telefoon 0174 515050
IBAN NL71 RABO 0340341610 · KvK Den Haag 27230471 · Btw-nummer NL8000.78.378.B01 · [email protected] · www.vanderendegroep.nl
Pagina 17 van 21
7. Failures
Before attempting to resolve any problem, always disconnect the pump from the power supply and
depressurise it.
Problem
Cause
Solution
Electric motor does
not work
Faulty circuit breaker
Check/replace all breakers
Thermal protection activated Reset thermal protection
Cord/plug defective
Check/replace power cord and plug
Pump fails to reach
pressure
Not properly vented
Open relief valve to let air out, then close
Relief valve is open (if used)
Shut relief valve
Inlet pressure too low
Water reservoir level too low or empty.
Check low-water float.
Make sure the inlet pressure pump is on.
Check the filter for contamination.
Check the inlet pressure protection.
No fluid flow
Control inlet/suction pipe, inlet pressure pump or
reservoir
Collars defect
Contact supplier
Overflow valve defect
Contact supplier
Pressure fluctuates Contaminated suction filter
Clean filter
Porous inlet hose
Replace hose
Overflow valve defect
Contact supplier
Hoses/couplings incorrectly
installed
Check hoses/couplings
Pump “bumpy"
Dirty and/or faulty valves
Contact supplier
Pump drawing in air
Check suction connection for cracks and/or holes
Pump leaks water
Loose coupling or bolts
Check couplings and bolts
Otherwise, contact supplier
Loose hose or hose clamps
Check hoses and hose clamps, tighten or replace
as necessary
Collars leak
Contact supplier
Pump leaks oil
Defective seals
Contact supplier
Table 7 Troubleshooting