www.valtir.com
13
Revision F November 2022
Figure 5
8) Placement of inner cones - Energite
®
III
Place the appropriate inner cones on the ledge inside the barrel for the 90, 180 and 320
kg (200, 400 and 700 lb.) modules. (The 640 and 960 kg modules do not require a cone
insert.) Refer to Page 9 (Figure 1A) of this Manual for a drawing and description of the
module components.
Note:
The same Energite
®
III cone is used for the 90 and 180 kg (200 and 400 lb.)
modules. Be sure that all cones are in the proper position (See Figure 6A).
Figure 6A Energite
®
III System
9) Placement of inner cones – Fitch
®
For a 200 lb. module place the Unicore on the top shelf (17”); fill to the scribe mark (FILL
TO HERE FOR 200#) resulting in a 7” sand depth and a 12” void at top.
For a 400 lb. module place the Unicore on the top shelf (17”); fill to the scribe mark (FILL
TO HERE FOR 400#) resulting in a 10.5” sand depth and a 8.5” void at top.
For a 700 lb. module place the Unicore on the second shelf from the top (14”); fill to the
scribe mark (FILL TO HERE FOR 700#) resulting in a 16” sand depth and a 12” void at
top.
For a 1400 lb. module place the Unicore on the third shelf from the top (8.5”); fill to the
scribe mark (FILL TO HERE FOR 1400#) resulting in a 27.5” sand depth and no void at
top.