background image

 

       

 

          

     

ADCA

 

                            

 

VAL

S

TEAM

 

ADCA

                     

 

 

 

IMI 9.101 E 02.17 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
CE Marking: 

This product has been designed for use on water, steam, air and other gases which are in Group 2 of 

the European PED-Pressure Equipment Directive in use and it complies with those requirements. 
All the sizes fall within category 2, DN100 pump falling in the category IV and PPA-14 falling in the category III. The 
products carry the CE mark.

 

 

 

 

 

 

 

If malfunction of any other equipment or system operation failure may result in a dangerous overpressure, over 
temperature or even vacuum condition, a safety device must be included in the system to prevent such 
situations. 

Do  not  touch  the  equipment  without  appropriate  protection  during  working  operation  because  it  may  conduct 
heat if the used fluid is at high temperature. 

Before  starting  maintenance  be  sure  that  the  equipment  is  not  pressurized  or  hot.  Even  if  upstream  and 
downstream isolating valves have been closed care should be taken since fluid under pressure may be trapped 
between them. 

The equipments must be used within the working temperature and pressure limits laid down for them, otherwise 
they may fail (refer to nameplate and/or IS- Information Sheet). 

Manual  handling  of  products  may  present  a  risk  of  injury.  You  are  advised  to  assess  the  risks  taking  into 
account the task, the individual, the load and the working environment.  

Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine ADCA 
replacement parts. 

0,80 kg/dm3

5º  Engler

10 bar

0,5 bar

11,2 l

Minimum motive pressure

Pump discharge per cycle DN25 to DN40

APPLICATION LIM ITS POP LC

Minimum density

Maximum viscosity

Maximum motive pressure

0,80 kg/dm3

5º  Engler

10 bar

0,5 bar

16 l

25 l

APLICATION LIM ITS POP-S AND PPO-14

Minimum density

Pump discharge per cycle DN80 x DN50

Maximum viscosity

Maximum motive pressure

Minimum motive pressure

Pump discharge per cycle DN25 to DN50

0,80 kg/dm3

5º  Engler

10 bar

1   bar

325 l

Minimum motive pressure

Pump discharge per cycle DN100 x DN100

APLICATION LIM ITS POP-S DN100

Minimum density

Maximum viscosity

Maximum motive pressure

0,80 kg/dm3

5º  Engler

10 bar

1 bar

21 l

APLICATION LIM ITS PPA-14

Minimum density

Maximum viscosity

Maximum motive pressure

Minimum motive pressure

Pump discharge per cycle DN80 x DN50

Summary of Contents for ADCAMAT POP

Page 1: ...ust sufficient to overcome back pressure The pressurized liquid opens the outlet check valve and discharge commences When the float reaches the minimum lower level it closes the steam or compressed ai...

Page 2: ...ng temperature and pressure limits laid down for them otherwise they may fail refer to nameplate and or IS Information Sheet Manual handling of products may present a risk of injury You are advised to...

Page 3: ...e to inappropriate handling during the transportation and storage See figure below for correct position in transportation Incorrect position Correct position INSTALLATION Account for over pressure con...

Page 4: ...ctly Ensure that the unit is leveled for proper operation External stresses that may be induced by the system due to pipe expansion etc can affect this product The necessary precautions are recommende...

Page 5: ...te the maintenance work 4 Replace and tighten the connections Don t forget to substitute the gasket 5 Consider the start up conditions TROUBLESHOOTING If the malfunctions cannot be solved with the hel...

Page 6: ...FLOAT AND GASKET 80 3 7 1 Set A 95 5500 225 PPA 14 SPRING SET 80 8 1 Set A 95 5500 325 PPA 14 COVER GASKET 80 3 1 Set A 61 1140 025A INLET ADCAMAT NON RETURN VALVE 25 9 2 1 A 61 1140 040A INLET ADCAMA...

Page 7: ...ADCA VALSTEAM ADCA IMI 9 101 E 02 17 PPA 14 PPO 14...

Page 8: ...y calibrated from the factory Do not unscrew the nuts Nr 17A and 19A 3 After replacing the valves and support make sure that the mechanism is working correctly by manually operating the float POP S DN...

Page 9: ...80 1 Tighten up screw nr 18C increase lower level 2 Untighten the screw nr 18C decrease lower level How to replace Inlet Outlet valves on PPA 14 1 With the float at the lowest position remove the bolt...

Page 10: ...on PRODUCTS RETURNING Information regarding any hazards and precautions to be considered because of contaminating fluids and residues or mechanical damage that may represent a health safety or environ...

Reviews: