This appliance is certifi ed for use from 0-4500ft. For 
altitudes above 4500ft see local codes.

Kit Contents

•  1 Pilot injector, see chart for identifi cation
•  1 Main burner injector, see chart for identifi cation
•  1 Minimum rate by-pass screw
•  1 Special bit for control cover screw (for RFBV/XB only)
•  1 Set of conversion labels

Tools Required

•  Wrenches, to disconnect gas line
•  Phillips (+) screwdriver, to remove burner module
•  Small jewelers size fl at blade screwdriver, to set pressure
• Small 

fl at blade screwdriver, to release pressure tap on 

valve

•  Needle Nose Pliers, to remove by-pass screw
•  Hex Allen wrench, 4 mm or 5/32”, to remove pilot injector
•  Special 2-pin screwdriver tip, supplied with kit, to 

remove valve cover

•  Manometer, to set pressure

Fireplace Models

RF24DVN

RF24IDN

RF24DVP

RF24IDP

RF24BN

RF24XBN

RF24BP

RF24XBP

Gas

Natural

Propane

Natural

Propane

Altitude (Ft)

0–4,500 Feet

Input Max. (Btu/h)

24,000

24,000

20,500

19,000

Input Min. (Btu/h)

10,500

10,500

12,500

12,500

Manifold pressure (in w.c.)

3.95

9.5

3.7

10.5

Min. Supply pressure (in w.c.)

5.0

11.0

5.0

11.0

Max. Supply pressure (in w.c.)

10.5

14.0

10.5

14.0

Main Burner Injector

82-580

92-260

82-580

92-200

Pilot Injector

62

30

62

30

By-Pass Screw

160

105

185

125

Specifi cations

© 2011 Miles Industries Ltd. All rights reserved.

WARNING

This conversion kit shall be installed by a 
qualifi ed service agency in accordance with 
the manufacturer’s instructions and all appli-
cable codes and requirements of the authority 
having jurisdiction. If the information in these 
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may 
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency 
is responsible for the proper installation of this 
kit. The installation is not proper and complete 
until the operation of the converted appliance 
is checked as specifi ed in the manufacturer’s 
instructions supplied with the kit.

Use this manual in conjunction with the instal-
lation manual supplied with the appliance.

Gas Conversion Kits

RA24NK (DV), RA24PK (DV) RA24BN (BV), RA24BP (BV)

Installation Instructions

Use with 

Valor Retrofi re Heater Models RF24D, RF24B, RF24ID or RF24XB ONLY