Safety First.

Valor fires are CE Approved and designed to meet the appropriate British Standards and Safety

Marks.

Quality and Excellence.

At the heart of every Valor fire.

All Valor fires are manufactured to the highest standards of quality and excellence and are

manufactured under a BS EN ISO 9001 quality system accepted by the British Standards Institute. 

The Highest Standards

Valor is a member of the Society of British Gas Industries which works to ensure high standards of

safety, quality and performance.

Careful Installation

Valor is a Corgi registered company. All our gas fires must be

installed by a competent Corgi Registered Installer in accordance 

with our Installer Guide and should not be fitted directly on to a 

carpet or floor of combustible material.

Valor Heating, Erdington, Birmingham B24 9QP

Because our policy is one of constant development and improvement, details may vary slightly from

those given in this publication 

© Valor Heating

Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication.

Valor Folium Format U/down 12/4  5/22/00  9:33 AM  Page 2

Summary of Contents for regency 328

Page 1: ...IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintained satisfactorily However if further information is required our Valor adv...

Page 2: ...ndards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance with our I...

Page 3: ...ting the radiants 9 Full operating checks 9 Control setting check 9 Fitting bottom panel trims 10 Spillage check 10 Fitting dress guard 11 Final review 11 Servicing parts replacement 11 Replacing radi...

Page 4: ...ers to work to recognised standards In the United Kingdom the installation must also be in accordance with A These instructions B All the relevant parts of local regulations C The current edition of t...

Page 5: ...system conforming to BS1289 The appliance is suitable for installations conforming to older versions of BS1289 as well as the current edition The flue blocks must have a minimum width not less than 63...

Page 6: ...bottom of the flue spigot See figure 2 2 7 The front face of the fireplace should be reasonably flat to ensure that a good seal can be made with the closure plate 2 8 The minimum clearance from the to...

Page 7: ...ting to install it is worth checking that the piezo electric spark ignition system operates satisfactorily To initiate the spark depress the control knob and while keeping it depressed turn to the 1 I...

Page 8: ...ther floor covering To achieve this the bottom of the closure plate must also be at least 102mm above the finished floor covering The centre of the flue spigot hole will be at least 486mm above the fi...

Page 9: ...safety and servicing 4 3 3 The supply pipe must be of a rigid material e g copper A flexible connection must not be made 4 3 4 Pressure check the installation pipework for gas soundness in accordance...

Page 10: ...nd tighten their securing screws 5 3 SPILLAGE CHECK A spillage check must be made before leaving the installed appliance with the customer 5 3 1 Close all doors and windows in the room containing the...

Page 11: ...the radiants 6 6 Advise that any cleaning must only be carried out when the fire is off and cold 6 7 Mention that the radiants may become brown with use that this is quite normal and has no adverse e...

Page 12: ...cage is cleaned before refitting Make sure that it locates squarely onto the pilot unit without any gaps between the cage edges and the pilot unit 7 4 TO REMOVE THE BURNER GAS TAP PILOT ASSEMBLY 7 4...

Page 13: ...ing the split pin 7 8 TO REMOVE THE COMPLETE FIRE TO CHECK CHIMNEY FOR DEBRIS 7 8 1 To gain access see section 7 2 7 8 2 Remove the radiants and store in a safe place 7 8 3 Remove the floor plate 7 8...

Page 14: ...levels of personal safety and performance efficiency it is essential that the opening at the back of the fire and the flue are kept clear of any form of obstruction It is possible that deposits of mo...

Page 15: ...leaned with a damp cloth and dried with a soft duster Obstinate marks can be removed from the guard and trims using soapy water Never use abrasive cleaners The radiants can be cleaned with a soft brus...

Page 16: ...pilot The pilot flame can be seen through the opening immediately below the centre radiant Figure 2 If the pilot does not light turn the control knob to OFF and try again In the unlikely event of fai...

Page 17: ...will automatically shut off the supply of gas to the fire if for any reason the pilot goes out If this device does operate or if the fire is turned off accidentally or intentionally always wait three...

Page 18: ...IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintained satisfactorily However if...

Page 19: ...ndards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance with our I...

Page 20: ...you care for your Valor gas fire Please read thoroughly before using and keep for future reference We trust that these instructions give sufficient details to enable this appliance to be operated and...

Reviews: