Valor regency 328 Installation & Servicing Instructions Manual Download Page 17

1.

As with any gas appliance, this fire must be
installed by a competent person in
accordance with the latest edition of the
gas safety (installation & use) regulations.

2.

If the fire is intended to be installed to a
chimney which was previously used for
solid fuel, please note that the chimney
must be swept prior to installation.

3.

On no account must the fire stand on
carpets or other combustible
materials. The fire must stand behind a
non-combustible hearth surface at least
880 mm wide and 300mm from front to
back. The hearth material must be at least
12.5mm thick. The top surface should be
50mm above floor level to discourage
placing carpets, rugs or other combustible
materials over it.

4. 

The minimum clearance from the top
surface of the fire to the underside of any
shelf  made from wood or other
combustible materials is as follows:-

For a shelf up to 150mm deep
Minimum height = 203mm

For a shelf deeper than 150mm
203mm + 12.5mm for every 25mm

depth over 

150mm.

5.

It should be appreciated that although this
appliance conforms to all the applicable
standards, it is a heating appliance and
certain parts of its surface will become hot. 
A suitable guard which complies with BS
6539 or 6778 should be used for the

protection of young children, the elderly
and the infirm.   Such a guard is also
recommended for the protection of pet
animals.

6.

Always switch the fire off and allow to cool
before cleaning or carrying out any
maintenance.

7.

Never hang clothing, towels or any other
fabrics over the fire.

8.

This fire is fitted with a device which will
automatically shut off the supply of gas to
the fire if, for any reason, the pilot goes out.
If this device does operate or if the fire is
turned off accidentally or intentionally,
always wait three minutes before
attempting to relight.

9.

Soft wall coverings (e.g. embossed vinyl
etc.) which have a raised pattern, are easily
affected by heat. They may, therefore,
scorch or become discoloured when close
to a heating appliance. Please bear this in
mind when having a heating appliance
installed and when redecorating.

When operating your fire for the first time, some 
vapours may be given off which may cause a
slight odour and could possibly set off any smoke 
alarms in the immediate vicinity. These vapours 
are quite normal with new appliances. They are 
totally harmless and will disappear after a feW
hours use.
It is quite common for the radiants to take
on a brown tint after a period of use. This is
normal with all types of ceramic radiant and has
no adverse effect whatsoever on the performance
or safety of the appliance.

Thank you for choosing this Valor gas appliance.
This fire has been designed to give years of
trouble-free service. To maintain its optimum
performance, advantage should be taken of the
regular servicing and inspection services
available for gas appliances. For Valor servicing
ring 0345 626 341 (Local rates apply). Annual
servicing is recommended.

Page 4

USERS INSTRUCTIONS

1.APPLIANCE DATA

PLEASE NOTE

IF YOU SMELL GAS

DON’T SMOKE
EXTINGUISH ALL NAKED FLAMES
DON’T TURN ELECTRICAL SWITCHES ON OR OFF
TURN OFF THE GAS SUPPLY AT THE METER
OPEN DOORS AND WINDOWS TO GET RID OF
THE GAS
IMMEDIATELY CALL THE GAS EMERGENCY
SERVICE- SEE YOUR LOCAL TELEPHONE
DIRECTORY

Valor Folium Format U/down 12/4  5/22/00  9:33 AM  Page 17

Summary of Contents for regency 328

Page 1: ...IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintained satisfactorily However if further information is required our Valor adv...

Page 2: ...ndards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance with our I...

Page 3: ...ting the radiants 9 Full operating checks 9 Control setting check 9 Fitting bottom panel trims 10 Spillage check 10 Fitting dress guard 11 Final review 11 Servicing parts replacement 11 Replacing radi...

Page 4: ...ers to work to recognised standards In the United Kingdom the installation must also be in accordance with A These instructions B All the relevant parts of local regulations C The current edition of t...

Page 5: ...system conforming to BS1289 The appliance is suitable for installations conforming to older versions of BS1289 as well as the current edition The flue blocks must have a minimum width not less than 63...

Page 6: ...bottom of the flue spigot See figure 2 2 7 The front face of the fireplace should be reasonably flat to ensure that a good seal can be made with the closure plate 2 8 The minimum clearance from the to...

Page 7: ...ting to install it is worth checking that the piezo electric spark ignition system operates satisfactorily To initiate the spark depress the control knob and while keeping it depressed turn to the 1 I...

Page 8: ...ther floor covering To achieve this the bottom of the closure plate must also be at least 102mm above the finished floor covering The centre of the flue spigot hole will be at least 486mm above the fi...

Page 9: ...safety and servicing 4 3 3 The supply pipe must be of a rigid material e g copper A flexible connection must not be made 4 3 4 Pressure check the installation pipework for gas soundness in accordance...

Page 10: ...nd tighten their securing screws 5 3 SPILLAGE CHECK A spillage check must be made before leaving the installed appliance with the customer 5 3 1 Close all doors and windows in the room containing the...

Page 11: ...the radiants 6 6 Advise that any cleaning must only be carried out when the fire is off and cold 6 7 Mention that the radiants may become brown with use that this is quite normal and has no adverse e...

Page 12: ...cage is cleaned before refitting Make sure that it locates squarely onto the pilot unit without any gaps between the cage edges and the pilot unit 7 4 TO REMOVE THE BURNER GAS TAP PILOT ASSEMBLY 7 4...

Page 13: ...ing the split pin 7 8 TO REMOVE THE COMPLETE FIRE TO CHECK CHIMNEY FOR DEBRIS 7 8 1 To gain access see section 7 2 7 8 2 Remove the radiants and store in a safe place 7 8 3 Remove the floor plate 7 8...

Page 14: ...levels of personal safety and performance efficiency it is essential that the opening at the back of the fire and the flue are kept clear of any form of obstruction It is possible that deposits of mo...

Page 15: ...leaned with a damp cloth and dried with a soft duster Obstinate marks can be removed from the guard and trims using soapy water Never use abrasive cleaners The radiants can be cleaned with a soft brus...

Page 16: ...pilot The pilot flame can be seen through the opening immediately below the centre radiant Figure 2 If the pilot does not light turn the control knob to OFF and try again In the unlikely event of fai...

Page 17: ...will automatically shut off the supply of gas to the fire if for any reason the pilot goes out If this device does operate or if the fire is turned off accidentally or intentionally always wait three...

Page 18: ...IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintained satisfactorily However if...

Page 19: ...ndards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance with our I...

Page 20: ...you care for your Valor gas fire Please read thoroughly before using and keep for future reference We trust that these instructions give sufficient details to enable this appliance to be operated and...