![Valor regency 328 Installation & Servicing Instructions Manual Download Page 13](http://html1.mh-extra.com/html/valor/regency-328/regency-328_installation-and-servicing-instructions-manual_3812463013.webp)
7.6.4.
Replace in the reverse order. Make sure that
the control knob with spindle is correctly
turned to agree with the gas tap position
before refitting the split pin.
7.7.
TO GREASE THE GAS TAP
7.7.1.
Remove the gas tap complete with piezo
generator - see section 7.5.
7.7.2.
Remove the piezo generator as 7.6. and
remove the two screws from the head of the
tap.
7.7.3.
Remove the spindle and spring from the tap.
7.7.4.
Note the position of the slot in the plug.
Mark its position on the tap body.
7.7.5.
Rotate the plug and pull it out of the tap.
7.7.6.
Clean and grease the plug lightly with a
suitable grease. Do not apply excessive
grease. Particularly, make sure that the gas
ports are not restricted by grease.
7.7.7.
Push the plug back into the tap body. Line
up the slot in the plug with the mark
previously made on the tap body.
7.7.8.
Reassemble in the reverse order making
sure that the components are correctly
engaged. Check the operation of the tap and
piezo. Make sure that the control knob with
spindle is correctly turned to agree with the
gas tap position before refitting the split pin.
7.8.
TO REMOVE THE COMPLETE FIRE TO CHECK
CHIMNEY FOR DEBRIS.
7.8.1.
To gain access see section 7.2.
7.8.2.
Remove the radiants and store in a safe
place.
7.8.3.
Remove the floor plate.
7.8.4.
Undo the inlet connection at the elbow
located centrally below the burner.
7.8.5.
If wall mounted, remove the two lower fixing
screws located in the back panel below the
burner then remove the two upper screws
accessible through the upper canopy grill.
Lift the fire away from the wall.
7.8.6.
If hearth mounted, pull the fire away from
the wall. Take care that the
levelling screw heads do not scratch the
hearth surface.
7.8.7.
Remove the closure plate from the chimney
opening.
7.8.8.
Inspect the opening and clear away any
debris from the base of the flue.
7.8.9.
Reseal the closure plate and refit the fire in
the reverse order.
Page 13
INSTALLATION & SERVICING INSTRUCTIONS
SHORTLIST OF SPARES
figure 10
KEY DESCRIPTION No. OFF
MAKER’S
PART No.
A Gas tap
1
544609
B Piezo generator
1
536939
C Injector Upper Bray
cat 28 size 120
1
544619
D Injector lower Bray
cat 28 size 250B
1
545199
E Pilot unit
1
545949
G Inlet elbow
1
532519
H Control knob
1
544659
J Radiant
3
544649
K Dress guard
1
523689
L Dust cage
1
567619
Valor Folium Format U/down 12/4 5/22/00 9:33 AM Page 13