background image

SAFETY

Do 

have the fire installed by a competent person. In the United Kingdom, installation

must be in accordance with the latest edition of the Gas Safety (installation & use) 
Regulations. In the Republic of Ireland, installation must be in accordance with all 
national and local regulations in force. 

Do 

have the chimney swept prior to installation if it was previously used for solid fuel.

Do 

have the fire installed in accordance with the installation instructions

Do 

provide a minimum clearance of 750mm from the top surface of the hearth to any 

shelf made of wood or other combustible material where the shelf is not more than 
150mm deep. For a shelf deeper than 150mm, add 12.5mm to the clearance for every
25mm of additional shelf depth.(See graph1)

Page 4

OWNER GUIDE

IF YOU SMELL GAS

DON’T SMOKE
EXTINGUISH ALL NAKED FLAMES
DON’T TURN ELECTRICAL SWITCHES ON OR OFF
TURN OFF THE GAS SUPPLY AT THE METER
OPEN DOORS AND WINDOWS TO GET RID OF THE GAS
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE – SEE YOUR LOCAL TELEPHONE
DIRECTORY

Graph 1. Combustible shelf clearances

Summary of Contents for quantum 746

Page 1: ...NCE IS FOR USE WITH PROPANE GAS G31 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE We trust that these instructions give sufficient details to...

Page 2: ...s a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company All our gas fires mu...

Page 3: ...REFITTING CERAMIC PEBBLES 12 MAINTENANCE 16 Owner Replaceable Parts 16 Regular maintenance 16 Servicing 16 USEFUL TELEPHONE NUMBERS 17 This gas fire is designed to meet the most stringent quality perf...

Page 4: ...the installation instructions Do provide a minimum clearance of 750mm from the top surface of the hearth to any shelf made of wood or other combustible material where the shelf is not more than 150mm...

Page 5: ...discoloured when close to a heating appliance Please bear this in mind whenever you are considering redecorating Do provide a minimum side clearance as detailed in figure 1 Please bear this in mind if...

Page 6: ...APPLIANCE DIMENSIONS Page 6 OWNER GUIDE Figure 1 Appliance dimensions Quantum Urban...

Page 7: ...Carbon Monoxide detector The device will also automatically shut off the gas supply to the fire if the pilot flame goes out due to lack of oxygen or for any other reason If this device starts to repe...

Page 8: ...en repeat the ignition procedure Lighting the Main Burner Once the pilot light is established the main burner can be lit by depressing and turning the control knob anticlockwise to the High position S...

Page 9: ...s with a slightly damp cloth and then dry Do not use abrasive cleaners as these will scratch the fire surface Front surround Clean the metal parts with a slightly damp cloth and then dry If this does...

Page 10: ...ble fuel bed see section fuel bed refitting ceramic pebbles 1 Place the rear base coal in the firebox It should rest on the ledges at the rear sides of the burner unit When located gently move the rea...

Page 11: ...uld be upright 5 Place a type A coal between the front and rear base coals with the letter A upright The top of the coal should rest against the centre coal of the rear base coal as shown in figure 8...

Page 12: ...ect fuel bed only For Coal fuel bed see section Fuel bed refitting ceramic coals 1 Place the rear base pebble in the firebox It should rest on the ledges at the rear sides of the burner unit When loca...

Page 13: ...re 13 3 Hold pebble A upright with the arrow pointing to the top Place pebble A on top of the front base pebble The pebble should rest against the moulded pebble to its left See figure 13 4 Hold pebbl...

Page 14: ...rest against the side of the firebox See figure 17 8 Hold pebble F upright with the arrow pointing to the top Place pebble F between the front and rear base pebbles It should rest on top of pebble A B...

Page 15: ...th the arrow pointing to the top Place pebble I between the front and rear base pebbles It should rest against the side of the firebox See figure 21 12 Hold pebble J upright with the arrow pointing to...

Page 16: ...flues wherever situated are checked annually Servicing In the United Kingdom servicing can be carried out either by a Valor service engineer or a CORGI registered installer If you require your fire t...

Page 17: ...065 for all enquiries USEFUL TELEPHONE NUMBERS General advice about gas and your gas fire VALOR TECHNICAL HELPLINE 08706 061 065 To report faults or arrange for your fire to be serviced VALOR SERVICE...

Reviews: