background image

9

Code

Description

Part Numbers

569LFP Patina

569LFN Nickel

569LFB Black

1

Trim Panel

4002267PA

4002267N

4002267AZ

2

LH Side Lead-in Panel

4002268AZ

4002268AZ

4002268AZ

3

RH Side Lead-in Panel

4002269AZ

4002269AZ

4002269AZ

4

Lower Lead-in Panel

4002270AZ

4002270AZ

4002270AZ

5

Cement Board

4002568

4002568

4002568

6

LH Column Assembly

4002272

4002272

4002272

7

RH Column Assembly

4002274

4002274

4002274

8

Bottom Panel

4002282AZ

4002282AZ

4002282AZ

9

Roof Grille

4002101AH

4002101AH

4002101AH

10

Internal Baffle

4002402

4002402

4002402

11

Top Panel

4002276AZ

4002276AZ

4002276AZ

12

Window Frame Cover

4002279BY

4002279BY

4002279BY

13

Convection Baffle

4002277BY

4002277BY

4002277BY

14

Touch Control Wall Switch with wire

4001487

4001487

4001487

15

LH Stud Bracket

4002516

4002516

4002516

16

RH Stud Bracket

4002517

4002517

4002517

17

LH ZC Stand-off

4002570

4002570

4002570

18

Insulation

620B987

620B987

620B987

19

RH ZC Stand-off

4002569

4002569

4002569

Screws 8 x 3/8 (24)

100A757

100A757

100A757

Nuts 8 x 32 (4)

4001517

4001517

4001517

Repair Parts List

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

Designed and Manufactured by / for

Miles Industries Ltd.

 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA  V7H 3B1

Tel. 604-984-3496  Fax 604-984-0246

www.valorfireplaces.com

Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication.

Summary of Contents for Portrait 569 Ledge Front

Page 1: ...nd off Stand off Insulation Stud bracket Stud bracket Convection baffle Mounting frame Window frame cover Cement board Trim panel patina brushed nickel or black Trim panel lead in assembly 570FPB Fini...

Page 2: ...n under bottom of trim for air gap 3 5 16 84 mm cement board and drywall thickness 1 2 13 mm wall finish thickness over top of drywall max 1 25 mm 1 2 13 mm when using 570 Plate 6 5 8 168 mm dia 3 5 8...

Page 3: ...4 603 mm wide Minimum 12 3 4 324 mm Allow extra for rear vent elbow drywall 570 plate outline wall finish must be non combustible at top of opening gap must remain open for air flow cement board 23 3...

Page 4: ...sert the grille in the firebox by aligning one of its side edge to the edge of the firebox as indicated b Raise the grille up to cover the top firebox ports and hold with one hand Note The port cover...

Page 5: ...the wall cover plate to the outlet box k Replace the receiver in its position and as well as the antenna if deployed 8 Install the cement board on top of the appliance The board sits on the horizonta...

Page 6: ...o the holes in the top piece and the frame s right piece Fix the three pieces together from the outside with all tabs inboard 2 screws NOTE All the side tabs of the bottom top and internal baffle piec...

Page 7: ...el clearances if finish protrudes from plate Without 570 Plate 1 1 8 inch maximum 13 Lay the trim s front plate face down on a clean flat surface noting which end is the top as indicated Fix the lead...

Page 8: ...8 Wiring Diagram Touch Control Wall Switch Connector...

Page 9: ...002279BY 4002279BY 4002279BY 13 Convection Baffle 4002277BY 4002277BY 4002277BY 14 Touch Control Wall Switch with wire 4001487 4001487 4001487 15 LH Stud Bracket 4002516 4002516 4002516 16 RH Stud Bra...

Page 10: ...nt rieurs Plaque de finition 570FPB Concept foyer 530 et Plaque de finition 570FPB vendus s par ment tapes d installation 1 rigez la charpente d encastrement du foyer 2 Installez le foyer avec les sup...

Page 11: ...seur du panneau de b ton et du panneau de gypse 1 2 13 mm paisseur de la finition du mur par dessus le panneau de gypse max 1 25 mm 1 2 13 mm avec la plaque 570 6 5 8 168 mm diam tre 3 5 8 92 mm 7 1 8...

Page 12: ...inimum 12 3 4 324 mm Ajoutez de l espace pour l vacuation arri re panneau de gypse Finition du mur Mat riau au dessus de l ouverture doit tre incombustible Contour de la Plaque 570 cet espace doit res...

Page 13: ...du haut a Ins rez la grille dans la bo te de foyer en l alignant parall lement au bord de c t de la bo te de foyer tel qu indiqu b Soulevez la grille contre le panneau sup rieur de la bo te de foyer...

Page 14: ...si elle a t d plac e 8 Installez la panneau de b ton au dessus de l appareil Le panneau doit reposer sur les languettes du haut des supports de montage la charpente 9 Installez le panneau de gypse Qu...

Page 15: ...Tenez le d flecteur en place avec une main d Avec l autre main alignez les trous de fixation du c t droit du d flecteur avec les trous de la pi ce du dessus et ceux du support de montage droit Fixez...

Page 16: ...Plaque 570 finition sous la plaque max 1 2 po 13 mm finition autour de la plaque voir les d gagements pour manteau et tablette si la finition d passe en saillie de la plaque b Sans la Plaque 570 max 1...

Page 17: ...8 fils Marche Arr t Commutateur de r initialisation Veilleuse Soupape combin e 4 piles AA Compartiment piles tincelle R cepteur tincelle Thermocourant Bloc interrupteur Interrupteur marche arr t Inte...

Page 18: ...Bordure de fen tre 4002279BY 4002279BY 4002279BY 13 D flecteur de convection 4002277BY 4002277BY 4002277BY 14 Interrupteur mural avec fil 4001487 4001487 4001487 15 Support de montage gauche 4002516...

Reviews: