1
Vertical Termination Venting Configurations
See venting accessories list on pages 32–33 for allowable components.
Co-linear Venting into Existing Solid-Fuel
Burning Fireplaces and Chimneys
Co-linear adapter may be installed as top or rear
outlet—see
Conversion to Top Outlet for Solid Direct
Vent Co-axial Piping
in
Appliance Preparation
section
for conversion to top outlet.
Co-linear and co-axial venting may be combined
in a single venting system provided conversion is
done only once using approved components and
maintaining proper clearances;
” liners may only be installed into solid-fuel
burning fireplaces and chimney systems (no
combustible construction);
The appliance must not be connected to a
chimney flue serving a separate solid-fuel burning
appliance.
•
•
•
Flashing
2 x 3”
liners
24-1/2”
3” min.
bend radius
Co-linear
adapter
2 x 3”
liners
18” max.
horizontal run
Co-linear
adapter
530
engine
40’
max
8’
min
Approved co-linear
termination or approved
co-linear adapter
and approved
co-axial
termination
2 x 3” liners
3/4”
see required depth
with various fronts
25-1/4”
556CLA
25-1/4”
3/4”
556CLA
2 x 3”
liners
see required depth
with various fronts
Co-Linear installation into existing F/P
556CLA
Rear Mounted
556CLA
Top Mounted
Alternate to 556CLA/559CLT/559FSK Conversion
Co-Axial to Co-Linear
Adapter
10”
10”
3” Inlet & Exhaust
Collars
7-5/8” dia.
collar
559FSK Flashing Kit
559CLT Co-Linear Terminal
556CLA Kit
Terminal Cap
Co-Linear to Co-Axial
Adapter
Flashing