 Replacing  batteries

Low batteries signals: 
• Handset: battery icon on display shows 1 lit bar
• Holder: frequent beeps for 3 seconds when valve 

motor turns.

BEFORE changing the batteries, turn the stove o

 

(including pilot) and let it cool. 
The stove uses four 1.5 V AA 

alkaline

 batteries in a 

separate battery holder located next to the receiver 

under the 

fi

rebox and one 9V 

alkaline

 battery in its 

handset. Batteries should last one to two seasons, 

depending on usage. Removing the batteries in the 

o

-season will extend the battery life. 

To access the battery holder, 
• 

Madrona Traditional:

 

remove the barrier screen 

and the fret or the front.

• 

Madrona Modern: 

open the bottom access panel 

under the front. 

WARNING

Do not attempt to access the batteries 

while the stove is hot! Let the stove cool 

fi

 rst before touching it!

Caution

Do not use a screwdriver or other metallic 

object to remove the batteries from the battery 

holder or the handset! This could cause a short 

circuit.

To replace the batteries: 
1.  Open the bottom access panel or 

unhook the front. 

Be aware that 

the cast iron front is very heavy.

2.  Locate the battery holder near 

the controls under the 

fi

 rebox. Pull the battery 

holder out.

3.  Disconnect the battery holder wire. 

Do not pull 

on the wire!

4.  Remove the used batteries from the battery 

holder and replace with 4 new AA 1.5V 

alkaline

 

batteries. 

Do not mix new/used batteries.

5.  Reconnect the battery holder wire.
6.  Reinstall the battery holder near the controls.

Using Handset Wall Holder

Your stove equipment includes a wall 

holder to store the handset. If it hasn’t been 

installed, refer to the instructions in the stove 

Installation Manual.

Remote and wall holder

Caution

Do not put batteries in the receiver as leaking 

acid could damage its circuit board.

Battery holder

Battery holder located near the controls on 

bottom of stove behind access panel/fret

Stove

Receiver

Battery 

holder

Gas 

valve

Stove

Receiver

Battery 

holder

Gas 

valve

Summary of Contents for MADRONA MF28JN

Page 1: ...plier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer...

Page 2: ...er market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not conve...

Page 3: ..._________________________________________ ________________________________________________ Please ask your installer for these details if they are not already provided or see page 7 Welcome to Valor C...

Page 4: ...and other combustible objects sensi tive to heat or furniture within 36 inches 0 9 m around the stove Solid wood flooring in front of the stove if allowed may shrink during the heating season due to h...

Page 5: ...not for use with solid fuel Maintenance More frequent cleaning might be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circul...

Page 6: ...ly supervised when they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barrier is recommended if there are at risk...

Page 7: ...will have disappeared and the flames will be at their normal height Valor automatic gas shut o For your safety Valor appliance is fitted with a flame supervision device which will shut o the gas supp...

Page 8: ...e Bed Front Stove s controls behind front Madrona Traditional Stove s info card underneath Window Frame Window Bolt Window Bolt Info Card underneath rolled at rear Battery Holder Receiver Gas Valve Ga...

Page 9: ...of the stove Installation Manual Turn your stove OFF including pilot Press and hold button on remote or ON OFF button on wall switch If the flames are on they go down and you hear the valve motor win...

Page 10: ...ard the access access the switch Alternately remove all batteries from the battery holder next to receiver as well as from the handset Automatic shut o in certain conditions Your stove s remote contro...

Page 11: ...remove the batteries from the battery holder or the handset This could cause a short circuit To replace the batteries 1 Open the bottom access panel or unhook the front Be aware that the cast iron fr...

Page 12: ...rasive cleaners must not be used Be careful not to scratch the glass when clean ing See Cleaning your stove on page 13 Inspect the operation of the flame safety sys tem Pilot or Flame rectification de...

Page 13: ...cleaning it Remove Window 1 Unhook the front of the stove and set aside Attention The cast iron front is very heavy 2 Release the 4 spring bolts at the top and bottom of the window by pushing and tur...

Page 14: ...tle Wax Do not clean the glass while it is hot Always securely replace the windows and the barrier screen before lighting see next page If broken glass panes may only be replaced as a complete window...

Page 15: ...purposes make sure the barrier screen is re installed on the stove front after maintenance 5 Re install the front with barrier screen on the trim Be careful as it is heavy WARNING The window unit mus...

Page 16: ...erminal outdoors regularly to ensure that it is not obstructed by snow trees bushes leaves or other objects Inpect the vent system regularly We recommend at least once a year Checking pilot and burner...

Page 17: ...on how to replace the batteries Why do I hear popping or snapping noises As your stove heats and cools with normal use its metal parts will expand and contract which may cause some noise This is perf...

Page 18: ...least once every year by a qualified service technician Contact our dealer quoting the model and serial numbers if possible These numbers can be found on the stove information card attached to the sto...

Page 19: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Page 20: ...et 4 5 meters of the replace Do not leave the handset on the mantel or hearth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up se...

Page 21: ...MAN Manual Mode Manual ame height adjustment TEMP Daytime Temperature Mode When pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjusts to reach D...

Page 22: ...n each 24 hour cycle Programs P1 and P2 must be set in the following order during a 24 hour cycle P1 P1 P2 and P2 Day Time temperature high program period Night Time temperature low program period Def...

Page 23: ...extended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months a...

Page 24: ...Notes...

Reviews: