Application
The HeatShift
®
convection duct kit redistributes the
warm air
ȵ
ow away from the
ȴ
replace opening to
a more desirable location using natural convection
without use of a fan.
Plenums LKD1, LDK3, LDK4 or LDK9:
the warm air
ȵ
ow
is relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room.
Termination Plates LDK7:
the warm air
ȵ
ow is
discharged through a gap (min. 2-1/2”) between the wall
above the
ȴ
replace and the ceiling.
LDK7’s discharge
opening must be located in the same room as the
fireplace.
The result is much cooler wall temperatures above the
ȴ
replace opening for locating televisions, artwork, etc.
Any kit, LDK1, LDK3, LDK4, LDK7 or LDK9 may be used
on LX2.
Approvals
The LDK1, LDK3, LDK4, LDK7 and LDK9 duct kits are
CSA approved for use only with Valor Series
ȴ
replaces
listed above—DO NOT use with any other models.
5-inch diameter duct used with this kit must be metal
and meet requirements of UL-181 Class 1 Air Duct.
Flexible aluminum duct is acceptable provided it meets
the UL-181 Class 1 requirements.
Note: These instructions are to be used in conjunction
with instructions regarding
ȴ
replace installation in this
manual.
Planning Installation: LX2 with HeatShift
®
Planning for use with the following
Valor Heater Models ONLY: 2200J, 2200K
Ʉ
WARNING
DO NOT cover or place objects in front of
or on top of air outlet(s). AVOID locating
outlet within 7 feet above
ȵ
oor level as
discharge temperatures are hot!
Ʉ
WARNING
When placing discharge close to ceilings,
staining or streaking may occur on light
colored ceilings due to any dust, etc. in air
ȵ
ow; placing plenum(s) lower on the wall
will help reduce the possibility of staining
or streaking.
Kits
There are 4 kits to choose from:
• LDK1—48” Plenum
• LDK3—14” Plenums (2), includes grilles
• LDK4—38” Plenum
• LDK7—Duct Termination Plates (2)—for wall valance
discharge ONLY
• LDK9—30” Plenum
Optional accessories
• LDK2—48” Finishing Frame, to use with LDK1
• LDK5—38” Finishing Frame, to use with LDK4
• LDK6— 5” dia Aluminum 2-ply Flex Kit—
2 x 10’–0” lengths, may be cut to required length
• LDK10—30” Finishing Frame, to use with LDK9
Appendix D - HeatShift System