9” (229 mm)
A
B
Non-combustible hearth
With optional
Fan: depth
+3” (76 mm)
Do not put
furniture or
objects within
36” (914 mm)
of the front of
appliance
Combustible Mantel Clearances
*Measure taken from the underside of the mantel to finished
hearth or surface that the unit is sitting on.
Finishing Materials
Combustible materials:
Material such as wood,
compressed paper, plant fibers, plastics or any material
capable of igniting and burning, whether flame-proofed
or not, plastered or un-plastered.
Non-combustible materials:
Material such as steel,
iron brick, tile, concrete or materials that bear the UL
mark for zero (0) fire rating.
Sidewall Clearances
Minimum
distance from side of appliance (liner box) to
combustible wall: 9” (229 mm).
Mantel
Projection A
1”
(25 mm)
4”
(101 mm)
8”
(203 mm)
14”
(355 mm)
Mantel
Height B*
34”
(864 mm)
36”
(914 mm)
38”
(965 mm)
40”
(1016 mm)
sidewall
WARNING
Some materials or items, although safe, may discolor, warp, crack, peel, and
so on because of the heat produced by the fireplace. Avoid placing candles,
paintings, photos, and other items sensitive to heat around the fireplace.
WARNING
HOT HEARTH!
The hearth in front of the fireplace
becomes very hot when the fireplace heats. Do not
use the hearth as a seat or shelf.
WARNING
HOT GLASS!
The use of a screen in front of
the glass is highly recommended particularly in
households with children.
8
Clearances
Summary of Contents for LEGEND G4 780IN (NG)
Page 40: ...40...