First time operation
When operating your new
fi
replace for the
fi
rst time,
some vapors may be released due to the burning of
curing compounds used during manufacturing. They
may cause a slight odor and could cause the
fl
ames
to be the full height of the
fi
rebox, or even slightly
higher, for the
fi
rst few hours of operation.
It is also possible that these vapors could set o
ff
any
smoke detection alarms in the immediate vicinity.
These vapors are quite normal on new
fi
replaces.
We recommend opening a window to vent the
room. After a few hours of use, the vapors will have
disappeared and the
fl
ames will be at their normal
height.
Valor safety gas shut-o
ff
For your safety, Valor
fi
replaces are
fi
tted with a
fl
ame supervision device which will shut-o
ff
the gas
supply if, for any reason, the pilot
fl
ame goes out.
This device incorporates a
fi
xed probe, which senses
the heat from the pilot
fl
ame. If the probe is cool,
the device will prevent any gas
fl
ow unless manually
lighting the pilot. See the full Fireplace and Lighting
Information card attached to the
fi
replace or as
reproduced in Appendix A of the Installation Manual.
Vent Safety Switch
Your
fi
replace is equipped with a vent safety switch
which, when activated, will turn o
ff
the burner and
pilot if the vent is blocked, disconnected, or if there is
excessive down draught.
If the safety switch is activated, wait for it to cool o
ff
before trying to light the appliance again. The safety
switch will cool o
ff
and reset itself automatically after
25 to 30 minutes.
In the event that the safety switch is activated again,
contact your dealer or a quali
fi
ed service technician
for inspection.
Should the safety switch require replacement, only
use parts supplied by Miles Industries.
Locating
fi
replace and lighting information
The Fireplace and Lighting Information card is located
under the
fi
rebox.
To access the card, remove the barrier screen, the
fret or bottom panel., and pull the card out.
There is important information on both sides of the
card. It must be left with the
fi
replace when you are
done.
Getting started
WARNING
Do not attempt to access the card while
the
fi
replace is hot! Let the
fi
replace cool
fi
rst before touching it!
739MN
FOR NATURAL GAS POUR LE GAZ NATUREL
750
24,000
6,500
3.2"
5.0"
4006176N/01
CIRCULATING FAN KIT 755CFK VENTILATEUR POUR CIRCULATION D'AIR 755CFK
#4003360-741, #4003293-742, #4003313-745, #4003426-765, #4004666 772
120V, 60Hz, LESS THAN 1A
120V, 60Hz, MOINS DE 1A
739N 10000
Fireplace
model
Serial
number