Valor Legend 736XN Installer'S & Owner'S Manual Download Page 8

8

4.3

LEAK TESTING

All piping and connections must be tested for leaks after
installation or servicing.
All leaks must be corrected immediately.

When testing for leaks:
1.

Make sure that the appliance control knob is at the

off 

position.

2.

Open the manual shut-off valve.

3.

Test for leaks by applying a liquid detergent or soap
solution to all joints. Bubbles forming indicate a gas
leak.

DANGER! NEVER USE AN OPEN
FLAME TO CHECK FOR GAS LEAKS

4.

Correct any leak immediately.

4.4

THERMOSTAT SHAFT RECONNECTION

1.

Turn the thermostat
control wheel fully
counterclockwise to
the lowest setting
(position 1). Turn the
thermostat spindle
fully
counterclockwise. See
figure 17.

2.

Release the lower
shaft from its parked
osition. Replace the
collar over the end of
the shaft with the “D”
hole at the bottom.

3.

Swing the shaft and
collar over the thermostat spindle.
Rotate the collar so that the “D” lines up with that in
the spindle and allow the collar to drop fully over the
thermostat spindle.

4.

Refit the “R” clip. The collar will have to be raised
slightly to align the holes. If it is not raised, the clip
may go below the end of the shaft. Check that the
collar rotates when the thermostat control wheel is
turned.

5.

REFIT THE FRONT FRAME

Place the front frame back in position and attach it to the
appliance case with the four screws previously removed.

6.

FIT THE FUEL BED

1.

Place the ceramic back wall in position at the back of
the firebox. Make sure that the brick pattern is the
right way up so that it will align with the side walls
pattern. See figure 18.

2.

Place the ceramic side walls in position at the sides of
the firebox. The sides are left and right handed. The
sides should be held in position at the top by the
angled brackets at the sides of the firebox and at the
bottom by the edges of the black bar at the front of
the firebox. See figure 19.

3.

Place the rear log in the retaining cradle behind the
rear burner rail. See figure 20.

4.

Place the center log in the retaining cradle between
the rear and front burner rails. See figure 21.

5.

Place the two front logs in position on the front log
support tray. It may be necessary to raise the center
log slightly in order to fit the left front log. Make sure
that the spacer blocks positioned on the back surface
of each front log rest against the front face of the
center log at the far left and right positions. See
figure 22.
Check that the fuel bed parts are secure.

Figure 17

Figure 18 Ceramic Back Wall

Figure 19 Ceramic Side walls

Figure 20 Rear Log

Figure 21 Center log

Figure 22 Front logs

Summary of Contents for Legend 736XN

Page 1: ...Massachusetts The gas piping and the final gas connection must be performed by a licensed plumber or gas fitter in the State of Massachusetts FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS T Open window...

Page 2: ...pors and liquids Never attempt to burn paper or any other material in the appliance Keep the area in front of the bottom grill clear to prevent obstruction of air flow to the appliance for combustion...

Page 3: ...677FSK vi 678FSK 21 2 Black Contoured Trim Covers 231 2 high x 361 2 wide vii 679FSK 21 2 Etched Champagne Contoured Trim Covers 231 2 high x 361 2 wide viii 2945 Brass Closure Plate Extends trim to...

Page 4: ...y 4 per 1000ft altitude However these appliances have been specifically field tested for high altitude performance Therefore deration of Natural Gas appliances is not necessary or recommended for inst...

Page 5: ...k that all the contents are in the pack and are undamaged 2 INSTALLING IN AN EXISTING FIREPLACE 2 1 PRE INSTALLATION PREPARATION 2 1 1 Closing Large Fireplace Openings This appliance is suitable for f...

Page 6: ...gure 3 The maximum horizontal vent pipe length is 8ft and the minimum vertical vent pipe height is 8ft For full details please contact your dealer Prepare the appliance and install in position in acco...

Page 7: ...the lower shaft back and park it in the slot opening in the right side of the appliance case figure 15d 4 2 GENERAL SUPPLY LINE REQUIREMENTS Openings for the gas supply line are provided at the back a...

Page 8: ...at control wheel is turned 5 REFIT THE FRONT FRAME Place the front frame back in position and attach it to the appliance case with the four screws previously removed 6 FIT THE FUEL BED 1 Place the cer...

Page 9: ...The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2psig 3 5kPa The appli...

Page 10: ...necessary serviced annually 14 OPERATING PROCEDURE For your safety this appliance is fitted with a flame supervision device which will shut off the gas supply if for any reason the pilot flames go out...

Page 11: ...g 1 3 Turn the control knob clockwise to OFF NOTE The knob cannot be turned from IGN to OFF unless it is pushed in partially Do not force 4 Wait five 5 minutes to clear out any gas then smell for gas...

Page 12: ...equests for spares 18 1 FOR THE OWNER If you require any attention to your appliance contact your supplier quoting the model number It is helpful if the appliance serial number is also quoted This wil...

Page 13: ...13 Figure 27 Burner Module Removal...

Page 14: ...Manufactured by HEATING BIRMINGHAM ENGLAND Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Ltd 1999 2000...