Valor Legend 736XN Installer'S & Owner'S Manual Download Page 4

4

ii.

 

As a zero clearance
installation fitted with the
optional part #700ZCK
kit, the appliance may be
installed into a minimum
sized enclosure
constructed of
combustible building
materials and connected
to an approved type “B”
vent. This kit (complete
with full installation
details) is available from
your dealer.

iii.

 

With a sidewall vent. For
this application, the
appliance must be
converted to a power vent
system using the
#720PVC power vent
conversion kit. This
allows the appliance to
sidewall vent through any approved 4” dia. vent
to a remote fan/hood up to 75 feet from the
appliance.

All installations must conform with local codes or, in the
absence of local codes, with the 

National Fuel Gas Code ANSI

Z223.1

 or the 

Canadian Installation Code CAN/CGA-149

.

Only qualified licensed or trained personnel should install the
appliance.
This appliance is not intended for use with a thermostat.

1.3

HIGH ALTITUDE INSTALLATIONS

This appliance has been tested for installation at high altitude
to CAN/CGA 2.17-M91. This standard simulates operation up
to 4500ft.
Natural Gas appliances comply with this standard without
deration of normal rated input.
Propane appliances require a 10% deration over 2000ft.

In Canada

, installations above 4500ft. will require approval

of the authority having jurisdiction.

In the USA

, the National Fuel Utilization Code specifies that

appliances installed at over 2000ft. altitude shall be derated by
4% per 1000ft. altitude. However, these appliances have been
specifically field-tested for high altitude performance.
Therefore, deration of Natural Gas appliances is not necessary
or recommended for installations up to 7000ft. For Propane
appliances a total deration of 10% for all altitudes above
2000ft. and up to 7000ft. is required. Above 7000ft. derate
Natural gas appliances by 4% for each 1000ft. above 7000ft.
Derate Propane appliances by 4% for each 1000ft. above
7000ft. plus 10%.

1.4

SUPPLY GAS

Model 736XN is for use only with Natural Gas. The natural
gas supply pressure at the appliance inlet connection should be
not less than 5”w.c. and not more than 10.5”w.c.
Model 736XP is for use only with Propane Gas. The propane
supply pressure at the appliance inlet connection should be not
less than 11”w.c. and not more than 14”w.c.
The supply connection to all appliances is 

3

/

8

” NPT.

1.4.1

Gas Feed Line

The supply gas feed line should enter the appliance through
one of the openings in the appliance case. Openings are
provided at the back and right side. See figure 3.
See section 4 for gas supply connection details.

1.5

CLEARANCES TO COMBUSTIBLE
CONSTRUCTIONS

The minimum clearances from any combustible constructions
at the front of the appliance are shown in figure 2. These front
clearances apply to all installations – Whether in a solid fuel
fireplace, new zero clearance construction or free standing. If
it is intended to fit the appliance in a combustible recess, the
Zero Clearance Kit #700ZCK (available from your dealer)
must be used as shown in figure 4.

Figure 3 Openings in Case

Fig. 4 New Zero Clearance Installation

Summary of Contents for Legend 736XN

Page 1: ...Massachusetts The gas piping and the final gas connection must be performed by a licensed plumber or gas fitter in the State of Massachusetts FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS T Open window...

Page 2: ...pors and liquids Never attempt to burn paper or any other material in the appliance Keep the area in front of the bottom grill clear to prevent obstruction of air flow to the appliance for combustion...

Page 3: ...677FSK vi 678FSK 21 2 Black Contoured Trim Covers 231 2 high x 361 2 wide vii 679FSK 21 2 Etched Champagne Contoured Trim Covers 231 2 high x 361 2 wide viii 2945 Brass Closure Plate Extends trim to...

Page 4: ...y 4 per 1000ft altitude However these appliances have been specifically field tested for high altitude performance Therefore deration of Natural Gas appliances is not necessary or recommended for inst...

Page 5: ...k that all the contents are in the pack and are undamaged 2 INSTALLING IN AN EXISTING FIREPLACE 2 1 PRE INSTALLATION PREPARATION 2 1 1 Closing Large Fireplace Openings This appliance is suitable for f...

Page 6: ...gure 3 The maximum horizontal vent pipe length is 8ft and the minimum vertical vent pipe height is 8ft For full details please contact your dealer Prepare the appliance and install in position in acco...

Page 7: ...the lower shaft back and park it in the slot opening in the right side of the appliance case figure 15d 4 2 GENERAL SUPPLY LINE REQUIREMENTS Openings for the gas supply line are provided at the back a...

Page 8: ...at control wheel is turned 5 REFIT THE FRONT FRAME Place the front frame back in position and attach it to the appliance case with the four screws previously removed 6 FIT THE FUEL BED 1 Place the cer...

Page 9: ...The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2psig 3 5kPa The appli...

Page 10: ...necessary serviced annually 14 OPERATING PROCEDURE For your safety this appliance is fitted with a flame supervision device which will shut off the gas supply if for any reason the pilot flames go out...

Page 11: ...g 1 3 Turn the control knob clockwise to OFF NOTE The knob cannot be turned from IGN to OFF unless it is pushed in partially Do not force 4 Wait five 5 minutes to clear out any gas then smell for gas...

Page 12: ...equests for spares 18 1 FOR THE OWNER If you require any attention to your appliance contact your supplier quoting the model number It is helpful if the appliance serial number is also quoted This wil...

Page 13: ...13 Figure 27 Burner Module Removal...

Page 14: ...Manufactured by HEATING BIRMINGHAM ENGLAND Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Ltd 1999 2000...

Reviews: