Valor Legend 736XN Installer'S & Owner'S Manual Download Page 12

12

16.

CLEANING

All cleaning should be carried out when the appliance is cold.
Normally the appliance should only need dusting. Dust etc.
can be brushed from the logs using a soft brush after detaching
the inner front unit and window – see installation instructions
sections 2.1.2 and 2.1.3. Dust etc. can also be removed from
the burners using a soft brush after removing the logs. When
cleaning the burners also check the aeration holes – see figure
24. If necessary brush clean the aeration holes.
If you are removing the logs, we suggest that they are
removed in the reverse order to that shown in the fuel bed
assembly instructions – see section 6. The logs, window and
inner front unit must be replaced as shown in the installation
instruction sections.

Coloring of the metal firebox with use is normal.

17.

CHECKS

1.

A periodic visual check of the pilot and burner
flames should be made. See figures 25 and 26.

2.

The appliance area must always be kept clear and
free from combustible materials, gasoline and other
flammable vapors and liquids.

3.

Keep the area in front of the bottom grill clear to
prevent obstruction of the air flow to the burners for
combustion.

4.

The flow of combustion and ventilation air must not
be obstructed. The venting system should be
examined by a qualified agency regularly. We
suggest annually.

18.

SERVICING

The repair parts are shown on the repair parts leaflet. Please
always quote part number and description with requests for
spares.

18.1

FOR THE OWNER

If you require any attention to your appliance, contact your
supplier quoting the model number. It is helpful if the
appliance serial number is also quoted. This will be found on
the appliance rating plate which is located on the left side of
the appliance case. It is visible when the inner front unit is
removed.

18.2

FOR THE SERVICE ENGINEER

To aid servicing of the burner and manifold parts or for
installation of the optional circulation fan #710CFK, the
burner module can be removed as follows – see figure 27.
1.

Remove the inner front and window – see sections
2.1.2 and 2.1.3.

2.

Take all the ceramic parts out of the firebox and store
carefully.

3.

Remove the front frame – see section 2.1.4.

4.

To allow clear access for disconnecting the supply
line elbow uncouple the thermostat shaft – see
section 4.1.

5.

Disconnect the gas supply line elbow at the appliance
inlet pipe union.

6.

Remove the two screws holding the burner module to
the firebox sides. These are situated over the bottom
outside flanges, one each side of the firebox.

7.

Remove the screw securing the sloping front heat
shield of the burner box to the appliance case.

8.

Carefully slide the burner module forward until just
clear of the appliance case.

9.

For most servicing operations the vent shutoff switch
wires can remain attached to the burner module. If
the burner module must be completely removed from
the appliance area loosen the thermocouple connector
at the back of the gas valve to detach the wires.

10.

When refitting, reconnect the thermostat control shaft
as described in section 4.4.

      

Figure 25. Burner Flames

Figure 26. Pilot Flame

Summary of Contents for Legend 736XN

Page 1: ...Massachusetts The gas piping and the final gas connection must be performed by a licensed plumber or gas fitter in the State of Massachusetts FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS T Open window...

Page 2: ...pors and liquids Never attempt to burn paper or any other material in the appliance Keep the area in front of the bottom grill clear to prevent obstruction of air flow to the appliance for combustion...

Page 3: ...677FSK vi 678FSK 21 2 Black Contoured Trim Covers 231 2 high x 361 2 wide vii 679FSK 21 2 Etched Champagne Contoured Trim Covers 231 2 high x 361 2 wide viii 2945 Brass Closure Plate Extends trim to...

Page 4: ...y 4 per 1000ft altitude However these appliances have been specifically field tested for high altitude performance Therefore deration of Natural Gas appliances is not necessary or recommended for inst...

Page 5: ...k that all the contents are in the pack and are undamaged 2 INSTALLING IN AN EXISTING FIREPLACE 2 1 PRE INSTALLATION PREPARATION 2 1 1 Closing Large Fireplace Openings This appliance is suitable for f...

Page 6: ...gure 3 The maximum horizontal vent pipe length is 8ft and the minimum vertical vent pipe height is 8ft For full details please contact your dealer Prepare the appliance and install in position in acco...

Page 7: ...the lower shaft back and park it in the slot opening in the right side of the appliance case figure 15d 4 2 GENERAL SUPPLY LINE REQUIREMENTS Openings for the gas supply line are provided at the back a...

Page 8: ...at control wheel is turned 5 REFIT THE FRONT FRAME Place the front frame back in position and attach it to the appliance case with the four screws previously removed 6 FIT THE FUEL BED 1 Place the cer...

Page 9: ...The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2psig 3 5kPa The appli...

Page 10: ...necessary serviced annually 14 OPERATING PROCEDURE For your safety this appliance is fitted with a flame supervision device which will shut off the gas supply if for any reason the pilot flames go out...

Page 11: ...g 1 3 Turn the control knob clockwise to OFF NOTE The knob cannot be turned from IGN to OFF unless it is pushed in partially Do not force 4 Wait five 5 minutes to clear out any gas then smell for gas...

Page 12: ...equests for spares 18 1 FOR THE OWNER If you require any attention to your appliance contact your supplier quoting the model number It is helpful if the appliance serial number is also quoted This wil...

Page 13: ...13 Figure 27 Burner Module Removal...

Page 14: ...Manufactured by HEATING BIRMINGHAM ENGLAND Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Ltd 1999 2000...