25
Planning
Framing—3-4 sided trims
• The 3 and 4-sided trims are adjustable to accomodate up to an additional 3/4” of tile or other
fi
nish
overtop of the 1/2” non-combustible wall board—Method 1.
• The appliance’s position within the framing cavity may also be adjusted for depth in the framing to
accomodate additional wall
fi
nish thickness “tucked” behind the trim—Method 2.
Appliance Depth in Framing—with 3 and 4-Sided Trims
3 and 4-Sided Trims—adjustable position
• wall
fi
nish thickness:
up to
3/4” + 1/2” non-
combustible board
• trim’s depth on appliance can be adjusted to
accomodate wall
fi
nish thickness
• wall
fi
nish thickness:
more than
3/4” + 1/2” non-
combustible board
• appliance’s depth can be adjusted in the framing to
accomodate additional wall
fi
nish thickness of up to
approximately 2”
• frame
fi
xing brackets
fi
xing position
• frame
fi
xing brackets
fi
xing position
Installation Method 1
Installation Method 2
Method 1
Method 2
Use slot
Use hole
1440 4-sided
trims
1435 3-sided
trims