13
Planning
Framing
48”
21”
44”
48”
21”
34-1/2”
between underside
of non-combustible board
and base of heater
1/2” thick non-combustible
board required above appliance
(not supplied) once installed in
framing - see
Any exposed surface directly in front
of the unit which is at a height of
less than 4” from the bottom of
the unit
must be non-combustible
.
May be reduced by
thickness of additional
non-combustible
ZDOOȴQLVKDSSOLHG
on top of 1/2”
non-combustible
board when using trims
other than 1430FFK
Fixed Framing Kit and
1430CIK Clean Install Kit
NOTE: This unit requires a
solid platform to support it.
Combustible framing allowed
EHQHDWKȴUHSODFH
Between underside of header and
base of heater. Base of heater must
EHDWȴQLVKHGKHDUWRZHYHU
please note that the 1440 4-sided
trim extends 1-1/2” below the base
of heater.
Increase cavity height
accordingly.
page 26
Stud Framing
NOTE
Use of optional HeatShift System affects framing.
See
Appendix D - HeatShift System
pages 79–98.