Horizontal Vent Terminal Locations

(see appliance manual for allowable vertical terminal locations)

• This direct vent appliance is designed to operate when 

an undisturbed airflow hits the outside vent terminal 

from any direction. 

• The minimum clearances from this terminal that must 

be maintained are shown in the figure below. Any reduc-

tion in these clearances could result in a disruption of 

the airflow or a safety hazard. Local codes or regulations 

may require greater clearances.

• The vent terminal must not be recessed into a wall 

or siding.

• The vent terminal should be positioned where it will 

not be covered by snowdrifts.

• Sidewall vent terminations within 7’ of grade or where 

easily accessible require a terminal guard such as the 

Valor 658TG or 845TG.

 Vent Termination

• The vent terminal must be located on a side wall or 

through the roof. Where possible, venting through the 

roof is preferable to sidewall venting to avoid products 

of combustion from accumulating in outdoor spaces.

• Typically, outdoor spaces are not totally enclosed by sol-

id continuous walls. When sidewall venting is used, the 

vent terminal will need to be located to avoid products 

of combustion from accumulating within the outdoor 

space or from entering the interior space through doors 

and windows. See clearances listed below with respect to 

openings to interior spaces.

• When a sidewall vent terminal terminates below an 

overhead cover (either permanent or temporary cover) 

at least 30% of the total perimeter wall area surrounding 

the outdoor space must be openings.

KEY VENT TERMINAL LOCATIONS - MINIMUM DISTANCES

Measured from the center of vent

MINIMUM 

CLEARANCE

 

Inches

Cm

A

Clearance above grade, verandah, porch, deck or balcony

12

30

B

Clearance to window or door that may be opened

12

30

C

Clearance to permanently closed window (recommended to prevent condensation on window) 

12

30

D

Vertical clearance to ventilated so

ɝ

  t located above the terminal within a horizontal distance of 2 feet (60 cm) 

from the center-line of the terminal 

18

46

E

Clearance to unventilated so

ɝ

  t

12

30

F

Clearance to outside corner

12

30

G

Clearance to inside corner

12

30

H

Horizontal clearance to center-line of meter/regulator assembly located within 15 feet (4.6

b

m) below the 

terminal

36

90

I

Clearance to service regulator vent outlet 

36

90

J

Clearance to non-mechanical air supply inlet to the building or the combustion air inlet to any other appliance

12

30

K

Clearance to a mechanical air supply inlet

72

180

L

Clearance above paved sidewalk or a paved driveway located on public property

Note:

 

A vent must not terminate directly above a sidewalk or paved driveway, which is located between two single-

family dwellings and serves both dwellings. 

THIS DOES NOT APPLY to direct vent, non-consdensing appliances in 

the Province of Ontario.

84

210

M

Clearance under a verandah, porch, deck or balcony

Only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the 

ȵ

 oor

12

30

Note: 

Local codes and regulations may require di

΍

 erent clearances.

V

G

A

Min. 72”

Max. 72”

Alcove detail 

(open on one 

side) Normal 

ceiling/so

ɝ

  t 

clearances 

apply.

Summary of Contents for GV60CKO

Page 1: ...ard Do not install electrical accessories fans lighting wifi when converting the appliance for use outdoors General notes regarding conversion This manual contains instructions for adapting natural ga...

Page 2: ...supplied separately to the outdoor receiver see installation instructions supplied with the kit Valve Wire Harness Red Yellow Wall Switch Harness RBWSK Remote Battery Wall Switch kit power connector...

Page 3: ...er and turning the gas shut off valve to the off position Upon ensuring the fireplace cannot be turned on you can then apply a weather protective cover over the front of the fireplace to help preserve...

Page 4: ...switch 1 Wait ve 5 minutes to clear out any gas then smell for gas including near the oor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the...

Page 5: ...m as an exterior wall If installed against an exterior wall we recommend the appliance enclosure or chase be constructed completely outside of the insultated building envelope and weather membrane The...

Page 6: ...fireplace insert 1600 See through Continuous insulated building envelope and weatherproof membrane is NOT interrupted by fireplace installation INSIDE INSIDE OUTSIDE Min weatherproof overhang in front...

Page 7: ...914 mm of front of appliance Min required weatherproof overhang Combustible Overhang 54 Min to Combustible Overhang non combustible construction permited lower Note Use of the optional HeatShift Syst...

Page 8: ...30 of the total perimeter wall area surrounding the outdoor space must be openings KEY VENT TERMINAL LOCATIONS MINIMUM DISTANCES Measured from the center of vent MINIMUM CLEARANCE Inches Cm A Clearanc...

Page 9: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the wa...

Page 10: ...ral fourni avec le foyer ou lorsque non fourni commandez le Porte piles et interrupteur mural RBWSK pour contr ler le foyer NE PAS UTILISER la manette thermostatique de t l commande fournie avec l app...

Page 11: ...s avoir rebranch toutes les connexions 7 V rifiez le fonctionnement de l interrupteur con sultez le guide du foyer ou de l interrupteur mural pour savoir comment fonctionne l interrupteur Harnais conn...

Page 12: ...gaz en position off En vous assurant bien que le foyer ne peut se rallumer vous pouvez en couvrir la devanture avec une paroi de protection l preuve des intemp ries afin d en pr server le fini et de...

Page 13: ...AUTOMATIQUE Bouton MAN ON 2 Assurez vous que le bouton de r glage des ammes 3 est au r glage le plus bas 3 g 1 Rep rez la veilleuse g 3 dans la bo te de foyer Sur l interrupteur mural appuyez le bouto...

Page 14: ...lure des murs ou non Note Le foyer ne peut tre install titre de mur ext rieur Si le foyer est install contre un mur ext rieur nous conseillons la construction de l encastrement ou de la charpente comp...

Page 15: ...existant Encastrement l preuve des intemp ries Enveloppe isolante continue de l difice et membrane l preuve des intemp ries NE SONT PAS interrompues par l installation du foyer Taille minimale du surp...

Page 16: ...du foyer Minimum 54 1372 mm jusqu au surplomb construction incombustible permise plus bas Surplomb minimum l preuve des intemp ries exig Note L utilisation du Syst me Heat Shift optionnel affecte les...

Page 17: ...l partir de l axe central du compteur r gulateur situ moins de 15 pieds 4 6 m sous la sortie d vacuation 36 90 I D gagement partir de la sortie d air vici du r gulateur 36 90 J D gagement partir d une...

Page 18: ...euses ou la r installation de pi ces r par es ou remplac es f Le propri taire original de l appareil sera responsable des frais d exp dition pour le remplacement de pi ces de m me que des frais de d p...

Reviews: