9
A
B
Non-combustible hearth
With optional
Fan: depth
+3” (76 mm)
Do not put
furniture or
objects within
36” (914 mm)
of the front of
appliance
Combustible Mantel Clearances
*Measure taken from the underside of the mantel to
fi
nished hearth or surface that the unit is sitting on.
Finishing Materials
Combustible materials:
Materials made of or surfaced
with wood, compressed paper, plant
fi
bers, plastics, or
other material that can ignite and burn, whether
fl
ame
proofed or not, or plastered or unplastered.
Non-combustible materials:
Material which will not
ignite and burn. Such materials are those consisting
entirely of steel, iron, brick, tile, concrete, slate, glass or
plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 °C
Mantel Pro-
jection A
0-6”
(0-152
mm)
8”
(203 mm)
10”
(254 mm)
12”
(305 mm)
Mantel
Height B*
33”
(838 mm)
35”
(890 mm)
37”
(940 mm)
39”
(990 mm)
Minimum
distance from side of appliance (liner box) to
combustible wall: 4” (102 mm).
Floor/Hearth Clearances
Combustible shims/supports may be used beneath
the appliance to level or raise the appliance within the
existing
fi
replace cavity.
Combustible
fl
ooring/hearths
in front
of the appliance
must be at a minimum of 4” (102 mm) below the bottom
of the appliance. The gas insert does not require a
hearth.
4” (102 mm)
Combustible Mantel—Left Side View
Installation Planning
Clearances
Sidewall Clearances
WARNING
Some materials or items, although
safe, may discolor, shrink, warp,
crack, peel, and so on because of the
heat produced by the fireplace. Avoid
placing candles, paintings, photos, and
other items sensitive to heat around
the fireplace.
WARNING
HOT GLASS! The use of a screen in front
of the glass is highly recommended
particularly in households with
children.
WARNING
HOT HEARTH / FLOOR! The hearth
or floor in front of the fireplace may
become very hot when the fireplace
heats. Do not use the hearth as a seat
or shelf. Solid wood flooring in front of
the fireplace (if allowed) may shrink
during the heating season due to heat.