Appendix C—Spare Parts

Description

Part 

Number

1

AutoFire Exhaust slide assembly

4006540

2

Exhaust slide gasket

4001662

3

Shrouds  (2)

4003295AZ

4

Side brick anchors (2)

4001283

5

LH Explosion relief assembly

4003681

6

RH Explosion relief assembly

4003680

7

Valve  access  panel

4002510

8

Valve access panel gasket

4002664

9

Valve access cover

4002806

10

Contemporary burner platform

4005341

11

Window frame assembly (inc. glass)

4004409

12

Hot glass warning plate

4003093

13

Burner module assembly (natural gas)

4005215S

Burner module assembly (propane gas)

4005346S

14

Top gasket

4003238

15

Side gaskets (2)

4002404

16

Bottom gasket

4003237

17

Thermocouple/pilot sealing plate

4002700

18

Pipe sealing plate

4004338

19

Switch bracket

4002566

20

Straight connector

220K891

21

Valve to elbow pipe

4005247

22

Thermocouple interrupter

4001037

23

GV60 valve assembly (natural gas)

4006011S

GV60 valve assembly (propane gas)

4006012S

24

36” 

fl

 ex pipe

4002475

25

Pilot Assembly (natural gas) 51

4006030

Pilot Assembly (propane gas) 30

4006031

26

Thermocouple (1000 mm)

4004801

27

Pilot Injector #51 (natural gas)

4000735

Pilot Injector #30 (propane gas)

4000736

28

Pilot Hood 2 Flame

4001756

29

Pilot shield

4004559AH

30

Extended Nut

4001855

31

Electrode

4001856

32

Injector nut

420K464

33

Injector elbow #750 (natural gas)

4000738

Injector elbow #260 (propane gas)

9730007

34

Insulation sleeve for ignition cable

4002244

35

Ignition cable (900 mm)

4004800

36

Cable interrupter

4001035

37

Switch with cable

4001036

38

Wiring harness

4001187

39

Receiver MAX (GX)

4002422

Description

Part 

Number

40

Auxiliary battery holder & cable

a

Battery  holder

4006553

b

Battery holder cable 1500mm

4006552

41

Handset GV60 MAX

4002251

42

Remote control wall holder

9000008

43

Driftwood Kit

700XDWK

44

Log & pebble set

4005542

45

RH rear log

4005536

46

LH rear log

4005535

47

LH cross log

4005537

48

White beach pebble

4003084

49

Black beach pebble

4003085

50

Small grey beach pebble

4003086

51

Beige beach pebble

4003087

52

Ash embers, grey - bagged (2)

4005812

53

Splinters, grey - bagged

4005813

59

Decorative Glass Murano

700XDGM

60

Pilot shield cover

4005342AH

61

Glass pad

4005343

62

Glass platform

4005332

63

Platform retainers (2)

4005333BY

64

FG-01 Clear 

fi

 reglass - bagged

4004521

65

Emberbed cover

4005531BY

66

Liner panels—complete set

a

Ledgestone V3

705LSLV3

b

Re

fl

 ective Glass

706RGL

c

Ceramic 

fl

 uted black

707FBL

d

Valor red brick

708VRL

67

Top panel

a

Ledgestone V3

4008182

b

Ceramic  black

4003202

c

Ceramic  black

4003202

d

Valor red brick

4003220

68

Rear panel 

a

Ledgestone V3

4008183

b

Re

fl

 ective Glass

4004704

b

Rear 

fi

 ller panel

4004804

c

Ceramic 

fl

 uted black

4003210

d

Valor red brick

4003219

69

Left side panel

a

Ledgestone V3

4008184

b

Re

fl

 ective Glass

4004705

b

LH 

fi

 ller panel

4003466

c

Ceramic 

fl

 uted black

4003208

Summary of Contents for AutoFire G3.5

Page 1: ...not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrica...

Page 2: ...yright Miles Industries Ltd 2022 All rights reserved Designed and manufactured for Miles Industries Ltd Valor Fireplaces 190 2255 Dollarton Highway North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 6...

Page 3: ...s 9 Before Installation 10 Overview 11 Venting 12 Overview 12 Preparation 13 Existing Fireplace Preparation 13 Installation 14 Window and Fan 14 Venting 15 Gas Supply 16 Liners 18 Fuel Beds 19 Install...

Page 4: ...eens are installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other co...

Page 5: ...designed and approved as a supple mental heater and provides the potential for most energy conservation when used while attended The use of an alternate primary heat source is advisable This unit is...

Page 6: ...sdiction Supply Gas Heater engine 700XN uses natural gas Heater engine 700XP uses propane gas The supply pressure must be between the limits shown in the Ratings section The supply connection is 1 2 N...

Page 7: ...ampagne Brass 721ED Edgemont Fronts 4003834 721EDN Polished 721EDV Vintage iron 721EDZ Bronze Backing Plates choose one 717BPB 3 sided floating 717BPBF 3 sided flat 719BPB 4 sided floating 36 1 4 W x...

Page 8: ...ght Side View Minimum Cavity Dimensions Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see the following section for allowable clearances A he...

Page 9: ...0 mm 39 990 mm Minimum distance from side of appliance liner box to combustible wall 4 102 mm Floor Hearth Clearances Combustible shims supports may be used beneath the appliance to level or raise the...

Page 10: ...sing the Pack Con tent sheet Also check that you have Fuel bed packed separately Liner panels packed separately Optional accessories if ordered Gas conversion kit if necessary Venting accessories Elec...

Page 11: ...ause of the heat produced by the fireplace Avoid placing candles paintings photos and other items sensitive to heat around the fireplace WARNING HOT HEARTH FLOOR The hearth or floor in front of the fi...

Page 12: ...outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height...

Page 13: ...ace Ash Retaining Curbs Some fireplaces particularly factory built have a raised curb at the front edge to retain ashes Check the dimensions carefully to ensure the 700 engine will fit behind any rais...

Page 14: ...d that where possible the fan be installed before the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan 6 power cord Remove Window The window is h...

Page 15: ...g it towards the back of the firebox 3 Fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure liners to collars with hose clamps included and 2 ta...

Page 16: ...pment shut o valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during pres...

Page 17: ...us must be no smaller than the size of a golf ball approx 1 3 4 or 44 mm as indicated Alternate Inlet Connection When the fireplace opening width is too narrow you may use common elbows and fittings n...

Page 18: ...l not to hook the pilot hood as you pull the burner up 3 To reinstall the burner fit the burner in the firebox insert ing the front tabs first in the lances Note Ensure that the front of the burner is...

Page 19: ...burner inserting the two pegs of the log in the holes of the burner 2 Place the right log on the right side of the ceramic burner inserting the two pegs of the log in the holes of the burner 3 Place t...

Page 20: ...3 Place emberbed cover over front of burner with tabs into recess part 4 Install the glass platform on top of the retainers 5 Carefully spread the glass on top of the burner within the platform openin...

Page 21: ...the frame as indicated below Window frame Bottom railing Hot Glass Plate WARNING The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage...

Page 22: ...left of the firebox in front of the re ceiver 3 With a sharp object press and hold the receiver s RESET button until you hear one short and one long beep Release the reset button after the second beep...

Page 23: ...e flames to appear more transparent and blue showing more ceramic e ects glow Decreasing aeration close will cause the flames to appear more yellow or orange showing less ceramic e ects glow Too littl...

Page 24: ...lation of trim Install Front Trim and Barrier Screen Install the front or trim chosen by the customer for their fireplace Install as well the barrier screen which is provided with the front or trim Sh...

Page 25: ...with the kit IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between...

Page 26: ...ptor Block black Battery Holder PILOT MAN Knob Combination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button Optional Wall Switch Kit Connector Thermocouple 8 Wire Cable bun...

Page 27: ...ter 46DVA GK 46DVA CLTA TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and o...

Page 28: ...RX VPHOO JDV 6TOP Follow LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWep 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER 21 2 VZLWFK LQ 21 SRVLWLRQ 0 1 NQRE L...

Page 29: ...he replace Do not leave the handset on the mantel or hearth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperatu...

Page 30: ...pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjust to reach Daytime Set Temperature Light Dimmer Mode Not available on this replace Fan Mode T...

Page 31: ...Press SET to scroll to TEMP Hold SET button until TEMP ashes To set Night Time Temperature increases temperature decreases temperature Press or wait to complete setting Setting Program Timers You can...

Page 32: ...extended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months a...

Page 33: ...as 4000738 Injector elbow 260 propane gas 9730007 34 Insulation sleeve for ignition cable 4002244 35 Ignition cable 900 mm 4004800 36 Cable interrupter 4001035 37 Switch with cable 4001036 38 Wiring h...

Page 34: ...ion Part Number d Valor red brick 4003217 70 Right side panel a Ledgestone V3 4008185 b Reflective Glass 4004706 c Ceramic fluted black 4003209 d Valor red brick 4003218 71 GV60 Valve repair kit 40045...

Page 35: ...rts 12 40 42 66 67 68 69 70 1 2 9 4 5 3 3 10 11 13 6 7 20 21 29 22 8 14 15 16 17 18 16 25 28 33a 33b 30 31 32 19 23 4 43 44 46 45 47 48 48 50 51 52 53 62 63 63 59 64 61 60 65 41 700XDWK 700XDGM 24 35...

Reviews: