This appliance is supplied with a flue restrictor for use where the flue draught is
excessive. Generally we recommend the
restrictor is NOT fitted where a precast flue,
metal flue box or a flue liner is used, however,
certain flues may work sufficiently to warrant
its use. There may however, be
circumstances where fitting the restrictor
causes the fire to fail the spillage test. In such
cases the restrictor will have to be removed.
After removal conduct the spillage check
again.
The restrictor is packed loose with the
appliance and is fixed with three screws (See
figure 14).
9.
There is a length of self adhesive foam
seal supplied with the fire. This will need to be
fitted to the outer rear edges of the side and top
flanges of the convector box. Cut a 485mm
length of foam seal. Be careful not to stretch
the seal when measuring. Remove the
protective backing from the foam seal and fit
this to the rear of the top flange (See figure 15).
Cut two 580mm lengths. Fit these to the rear
outer edges of the side flanges. Ensure that
there is no gap between the foam seals where
they meet at the top flange (See figure 15).