General Notes Regarding Conversion
The conversion may be done before or after the
appliance is installed into the cavity. However, the gas
must be connected to set the manifold pressure.
Prepare the Appliance
1. If the
fi
replace is already installed, remove the front
trim, the window, fuel bed. Be careful with fuel bed
as components are fragile.
2. Remove the fuel bed support (2 screws).
3. Remove the burner cover (2 screws).
4. Carefully remove the liner panels.
5. Remove the burner cover support (3 screws).
6. Using two wrenches, disconnect gas inlet from the
control valve.
7. Remove the burner plate (12 screws). It is necessary
to access the by-pass screw on underside of valve.
If the appliance has been burned previously, it may
be necessary to pry the burner module gaskets as
they tend to adhere when removed the
fi
rst time.
Replace Burner Injector
1. Undo burner supports (4 screws).
2. Unscrew the nut at the end of the burner fuel
supply line, and lift the burner and supports out of
the
fi
replace (complete with injector elbow at-
tached).
3. Unscrew and disengage the injector elbow. Be
aware that
four pieces sit between the elbow and
the burner, do not drop them
.
4. Exchange injector elbow from kit, verifying the new
injector before you install—see Speci
fi
cations table
on page 1. The injector number is stamped on the
corner of the elbow.
5. Exchange the air shutter from kit as its shape is dif-
ferent for each fuel.
6. Reassemble the burner, putting the
fl
at washer, ten-
sion washer, air shutter, and anti-
fl
ashback shield
back in order as shown below. Reconnect injector
Nut
Injector elbow
Anti-flashback
shield
Air shutter
different shape
for each fuel
Natural
Propane
Tension washer
(wavy)
Flat washer
2