Valor 739VNGK Installation Manual Download Page 1

WARNING

This conversion kit shall be installed by 

a quali

fi

 ed service agency in accordance 

with the manufacturer’s instructions and 

all applicable codes and requirements 

of the authority having jurisdiction. If 

the information in these instructions is 

not followed exactly, a 

fi

 re, explosion 

or production of carbon monoxide 

may result causing property damage, 

personal injury or loss of life. The 

quali

fi

 ed service agency is responsible 

for the proper installation of this kit. The 

installation is not proper and complete 

until the operation of the converted 

appliance is checked as speci

fi

 ed in the 

manufacturer’s instructions supplied with 

the kit.
Use this manual in conjunction with the 

installation manual supplied with the 

appliance.

739VNGK / 739VPGK Gas Conversion Kit

Use with Valor G3 739V Heater Models ONLY

INSTALLATION MANUAL

G3 739V

4009029-01

©2021, Miles Industries Ltd.

Kit Contents

• 1 Pilot injector

• 1 Main burner injector elbow

• 1 Air shutter

• 1 Minimum rate bypass screw

• 1 Set of conversion labels

Tools Required

• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) 

fl

 at blade screwdriver, to set pres-

sure

• Small 

fl

 at blade screwdriver, to release pressure tap 

on valve

• Needle nose pliers, to remove bypass screw
• Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot 

injector

• Manometer, to set pressure

Speci

fi

 cations

This appliance is certified for use from 0–4500 feet. For 

altitudes above 4500 feet, see local codes.

Model 739VN

739VP

Gas

Natural

Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (BTU/h)

24,000

24,000

Input Minimum (BTU/h)

13,000

13,000

Manifold Pressure (in w.c.)

3.2”

10.0”

Minimum Supply Pressure (in 

w.c.)

5”

11”

Maximum Supply Pressure (in 

w.c.)

10”

14”

Main Burner Injector Marking

82-750

92-260

Pilot Injector Marking

51

30

Min. Rate Bypass Screw

185

125

Summary of Contents for 739VNGK

Page 1: ...Models ONLY INSTALLATION MANUAL G3 739V 4009029 01 2021 Miles Industries Ltd Kit Contents 1 Pilot injector 1 Main burner injector elbow 1 Air shutter 1 Minimum rate bypass screw 1 Set of conversion l...

Page 2: ...rner module gaskets as they tend to adhere when removed the first time Replace Burner Injector 1 Undo burner supports 4 screws 2 Unscrew the nut at the end of the burner fuel supply line and lift the...

Page 3: ...cement minimum rate bypass screw and hand tighten using a screwdriver Allen key Refer to the Specifications table on page 1 for proper bypass screw the number is stamped on the barrel of the screw Byp...

Page 4: ...Valve Pry off Plastic Cap Front Face of Control Valve Pressure adjustment screw behind plastic cap Increases pressure Decreases pressure 4 Turn o the appliance remove the manometer and tighten the tes...

Page 5: ...INSTALLATION G3 739V Contenu du kit 1 Injecteur de veilleuse 1 Injecteur coude du br leur 1 Obturateur d air 1 Vis d indice minimum 1 Ensemble d tiquettes de conversion Outils requis Cl s tuyaux pour...

Page 6: ...r leur 3 vis 6 En utilisant deux cl s d branchez la conduite de gaz reli e la soupape gaz 7 Enlevez la plaque du br leur 12 vis pour acc der la vis d indice minimum sur le dessous de la soupape Si l a...

Page 7: ...oir la table la page 5 Le num ro de l injecteur est grav sur le coude 5 Remplacez l obturateur avec celui fourni avec la trousse car il est di rent selon le gaz utilis 6 R assemblez toutes les pi ces...

Page 8: ...savon Des bulles indiquent qu il y a une fuite de gaz Vis d indice minimum Soupape gaz AVERTISSEMENT NE JAMAIS UTILISER une flamme vive pour v rifier s il y a des fuites Corrigez imm diatement toute f...

Page 9: ...r 1 Rep rez le levier d ajustement de l obturateur 2 Glissez le levier vers la gauche ou vers la droite selon le besoin Voir le Guide d installation du foyer pour plus de d tails Levier dobturateur Ob...

Reviews: