background image

Tape Shut

Thank you for choosing a Valor Product

Postage
needed

Miles Industries Ltd.
190 - 2255 Dollarton Highway
North Vancouver, BC   V7H 3B1     
Canada

Fold here

Online Warranty registration at www.valor

fi

 replaces.com

Summary of Contents for 739-72JLN

Page 1: ...Retain this manual for future reference Please read this manual BEFORE installing and operating this appliance Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediate...

Page 2: ... Check Operation 30 Adjust Aeration if necessary 30 Install Handset Wall Holder 30 Install Front and Barrier Screen 31 Wiring Diagram 32 Approved Venting Components 33 Warranty 34 Spare Parts 35 2 Table of Content The information contained in this installation manual is believed to be correct at the time of printing Miles Industries Ltd reserves the right to change or modify any information or spe...

Page 3: ...ries Clothing or flammable material should not be placed on or near the appliance This unit must be used with a vent system as de scribed in this installation manual No other vent sys tem or components may be used This gas fireplace and vent assembly must be vented directly to the outside and must never be attached to a chimney serving a separate solid fuel burning appli ance Each gas appliance mu...

Page 4: ...risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk individuals a safe distance from the fireplace Keep the remote control handset out of reach of children at all times A wall mount storage holster is provided with your remote control handset Ensure that the fireplace including the pilot light is completely turned off when chi...

Page 5: ...ow Do not let children touch the glass or any parts of your fireplace even after it is turned off as it is still hot Use the barrier screen provided with the trim or a gate to reduce the risk of severe burns Keep the remote control handset out of reach of children Hot hearth floor surface The hearth or floor directly in front of the fireplace is very hot when the fireplace heats Even if constructed...

Page 6: ...ually lighting the pilot See full lighting instructions on page 11 of this manual Introduction Thank You For purchasing a Valor by Miles Industries Your new radiant gas heater is a technical appliance that must be installed by a qualified dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ...

Page 7: ...the wall switch malfunctions and will not turn off the fireplace wait 8 hours and the fireplace will automatically go to pilot You can access the controls inside your fireplace Alternately you can turn off gas supply In all cases call your dealer for service assistance How to Prevent Inadvertent Ignition Use one of the two following methods to ensure that your fireplace will not turn on when you don...

Page 8: ...et To communicate the handset should be within 15bfeet 4 5 meters of the ȴreplace Do not leave the handset on the mantel or hearth OFF turns the burner DQG WKH SLORW R DUJH ȵDPH EXWWRQ ȵDPHV XS VHWV KRXUV 6PDOO ȵDPH EXWWRQ ȵDPHV GRZQ DQG R VHWV PLQXWHV Current temperature F or C Current time 12 or 24 hour clock Handset sensor Battery status Turn Fireplace ON Press buttons until you hear a short be...

Page 9: ...nguishes the pilot This feature helps the consumer realize cost beneȴts by automatically eliminating energy consumption during non heating months and limited use The programmed length of inactivity to activate the system is speciȴed by the appliance manufacturer and cannot be altered in the ȴeld Low Battery Indication Handset The battery icon will show when the bat tery needs to be replaced Replac...

Page 10: ... gas 739PGK Conversion propane gas Other accessories 1265WSK Wall Switch Kit RBWSK Remote Battery Wall Switch Kit 755CFK Circulating Fan Kit Hearth Gate Hearth gates such as Cardinal s VersaGates are available at retail stores carrying safety products for children Required Kits Information accurate at the time of printing and subject to change without notice Optional Accessories Information accura...

Page 11: ... µ LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWep 3 AUTOMA7 1 7 21 ÀJ RFDWH WKH SLORW ÀJ LQVLGH RI ÀUHER 21 2 VZLWFK LQ 21 SRVLWLRQ 0 1 NQRE LQ 21 SRVLWLRQ VHW ODPH GMXVWPHQW NQRE WR ORZHVW VHWWLQJ 3 2Q WKH UHPRWH FRQWURO KDQGVHW SUHVV DQG KROG WKH RII EXWWRQ and large flame VLPXOWDQHRXVO D VKRUW DFRXVWLF VLJQDO FRQÀUPV WKH VWDUW KDV EHJXQ Further short acous...

Page 12: ...the flame safety system Pilot or Flame rectification device 4 Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Visual inspection should match that outlined in the appliance instruction manual Inspect primary air openings for blockage See Checking Pilot and Burner Flame section of this manual 5 Inspect condition of vent and vent terminal for s...

Page 13: ...brasive to ceramic glass and should be avoided Our dealers have had good results from the products listed below We cannot however guarantee the results of these products Brasso Polish Plus by Kelkem Cook Top Clean Creme by Elco White Off by Rutland Turtle Wax Do not clean the glass while it is hot Always securely replace the window and the barrier screen before lighting If broken the glass pane may...

Page 14: ...ted 7 Reinstall the front and barrier screen WARNING F O R S A F E T Y P U R P O S E ensure the barrier screen is re installed on the fireplace front after maintenance Servicing Maintenance Hot Glass Plate WARNING Failure to install the window correctly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage cause...

Page 15: ...from appliance to appliance depending on the type of installation and climatic conditions The appliance area must always be kept clear and free from combustible materials gasoline and other flammable vapors and liquids Inspect the vent terminal outdoors regularly to make sure that dirt snow insects leaves shrubs trees do not obstruct it Examine the whole vent system regularly We recommend annually...

Page 16: ... will extend the battery life Should the batteries lose power the control may be operated by manually turning the control knob at the valve or by turning off the valve at the switch To replace the batteries in the battery holder 1 The battery holder is located underneath the firebox behind the lower panel Unhook the panel Grab the battery holder and pull it out 2 Disconnect the battery holder 3 Rep...

Page 17: ...70 m in USA installations must be in accordance with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas utility to confirm For installations at elevations above 4 500 feet 1 370 m in Canada please consult provincial and or local authorities having jurisdiction Supply Gas Heater engine 739 7...

Page 18: ... wood flooring in front of the fireplace if allowed may shrink during the heating season due to heat WARNING Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other items sensitive to heat around the fireplace WARNING WARNING 739 72 fireplace Gas insert does not require a hear...

Page 19: ...uter Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clearances for allowable clearances Minimum width of fireplace opening at front 28 711 mm X 12 14 305 357 mm varies with outer trim options Y 20 1 4 514 mm 24 610 mm when using 763 Backing Plate QUALIFIED INSTALLER 19 ...

Page 20: ...l that can ignite and burn whether flame proofed or not or plastered or unplastered Non combustible materials Material which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof Materials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furn...

Page 21: ...ermination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to center of pipe Maximum offset angle 45 sweeping bend to allow for obstructions Venting Notes Where possible avoid joining flex pipes If joints are required use a approved connector and seal joints with...

Page 22: ... THIS FIRST 1 YOU NEED TO KNOW FROM THE HOMEOWNER what accessories surround etc will be installed with this fireplace 2 Unpack the appliance removing all items packed inside and around it Recycle the packaging 3 Check that you have everything using the Pack Content sheet Also check that you have Fuel bed Venting accessories Gas conversion kit if necessary Electrical accessories if necessary Surrou...

Page 23: ...m of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimensions section for detailed location of gas inlet Also take into consideration whether or not a fan or shut off valve will interfere when planning routing of the gas line Existing Glass Doors and Wire Screens Existing glass doors must be permanently removed prior to ...

Page 24: ...ide in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the firebox to facilitate its installation If the fan is retrofitted after the installation of the appliance the burner module will need to be removed Therefore we recommend that where possible the fan be ins...

Page 25: ...e firebox 3 Fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure liners to collars with hose clamps included and 2 tapping screws per liner 4 Slide the firebox onto the vent slider in the cavity taking care not to damage the liners Make sure that the rear edge of the slider is hooked over the cleat on the firebox Secure the vent slider to the...

Page 26: ...sing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during pressure testing may resulting regulator or valve damages and void the warranty Consult your dealer in case of damages X Pressure Test Points The minimum supply pressure is given in the sect...

Page 27: ... cross log Both front logs to rest slightly on the edge of the firebox window frame Center the front logs side to side in relation to the firebox Place it on the right pin located on the rear log Rest its other end in the crook of the front right log 5 Identify the middle cross log It does not have a hole underneath Place its narrow end on the flat depression in the rear log next to the right cros...

Page 28: ...om the front lower corner of the window reinstall it by sliding it between the glass and the frame as indicated Hot Glass Plate WARNING Failure to install the window correctly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in dangerous conditions Damage caused by incorrect window installa tion is not covered by the Valor warranty DANGE...

Page 29: ...e a heat resistant tie to gather any extra cable between the receiver and the holder Battery holder CAUTION DO NOT let the cable touch the burner plate above it will melt during operation Synchronize Remote Control The receiver and the handset of the remote control system must be initially synchronized before the first use 7 With a thin object press and hold the receiver s reset button until you h...

Page 30: ...ould be located away from any other heat source and not in direct sunlight as this may affect the temperature sensor located in the remote handset Installation Check Operation Turn the fireplace flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 8 9 Adjust Aeration if necessary Light the fire and all...

Page 31: ... with the heater The Contemporary Front is equipped with a barrier screen The barrier screen is designed specifically to prevent any contact with the glass of the fireplace which becomes hot during operation and remains hot when cooling 739 72 Trim Matt Black Front Overview trim sold separately Installation Installation 1 Install the outer surround to the engine according to the installation instr...

Page 32: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram Wiring Diagram Battery Holder 4 AA Batteries QUALIFIED INSTALLER 32 ...

Page 33: ...LTA TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and others 2280 Series AF3 35L TM ALK33 952703 TM ALT33 952704 Flashings Roof Flashing 0 12 6 12 46DVA F6 4DT AF6 TF 4FA SV4FA 4DF 0 12 5 12 949606012 Roof Flashing 7 12 12 12 46DVA F12 4DT AF12 TF 4FB SV4B 4DF12 6 12 12 12 9...

Page 34: ...nform to all applicable codes including national and local gas appliance installation codes and building and ȴre codes d The owner must comply with all operating instructions e The Company is not responsible for the labor costs to remove defective parts or re install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as ...

Page 35: ...osure Plate 4001136 4 Port Cover 4001820 5 Log Support 4006177 6 Top Mounting Bracket 4000136AZ 7 Side Mounting Brackets 2 4000135AZ 8 Window Assembly 4001378 9 Hot Glass Warning Plate 4003093 10 Burner Assembly natural gas 4006282CS Burner Assembly propane gas 4001376S 11 Burner Rail natural gas 4001665 Burner Rail propane gas 4001666 12 Injector Elbow natural gas 4000738 Injector Elbow propane g...

Page 36: ... 9 55 56 57 58 59 60 54 52 Natural gas Propane gas 18 20 25 21 22 23 24 19 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 41 14a 13a 47 48 49 43 44 45 46 50 61 natural gas propane gas 64 63 62 36 OWNER S INFORMATION ...

Page 37: ...on provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model Number 739 72JLN 739 72JLP Serial Number Date Purchase yyyy mm dd Dealer Customer Information First Name Last Name Contact Information Email Mailing Address Address City Province State Postal Zip Code C...

Page 38: ...Shut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplaces com ...

Reviews: