Connect Venting
IMPORTANT: This appliance’s venting system is room sealed and
therefore, does not require room air to be used in the combustion
process.
1. Rough-in two 3” diameter vent liners into the existing
chimney system from the roof. Be careful not to tear or
damage the liners in the process. It may be easier to
install both liners at the same time rather than one at a
time. Leave plenty of liners at the bottom to facilitate the
connection of the liners to the vent slider.
It is best to leave
the top termination until later.
Designate and mark the top and bottom of one liner as
“EXHAUST” to avoid confusion later.
2. Release the two screws retaining the vent slider to the
front of the
fi
rebox. Remove the slider from the
fi
rebox by
sliding it towards the back of the
fi
rebox.
3. Fit the two liners
ensuring that the
exhaust
liner is
connected to the identi
fi
ed “EXHAUST” vent collar
.
Secure liners to collars with hose clamps (included) and 2
tapping screws per liner.
4. Slide the
fi
rebox onto the vent slider in the cavity taking
care not to damage the liners.
Make sure that the rear
edge of the slider is hooked over the cleat on the
fi
rebox.
Secure the vent slider to the front of the
fi
rebox
with two screws removed earlier.
5. From the roof, pull the liners and
fi
t the
fl
ashing.
6. Fit the terminal
cap
ensuring that
the exhaust liner
is connected to
the exhaust vent
collar
. Secure with
8 screws provided.
7. Seal the terminal
and
fl
ashing from
water penetration
as required.
1
3
5
6
Installation
7
Vent slider
cleat
WARNING
Failure to position the parts in
accordance with these diagrams
or failure to use only parts
speci
fi
cally approved with this
appliance may result in property
damage or personal injury.
WARNING
!
4
2
QUALIFIED
INSTALLER
25