“Visage” front; Carefully lift the front surround.
Do
not lift it by the control knob.
Place it against the
fireplace front surface so that the two retaining
plates at the back of the surround are directly above
the two upper retaining brackets at the top of the
convection box. Lower the surround unit making
sure that the rear retaining plates locate fully over
the retaining brackets on the convection box (See
figure 18).
12.3
Swing the bottom control linking bar towards the
center of the fire to clear the front casting/surround.
Slide the front casting/surround sideways, if
necessary, to align the bottom fixing holes with
those in the convection box. Fix the bottom of the
casting/surround to the convection box with two
screws (See figure 19 or 20).
12.4
Align the hole near the bottom of the control
linking bar with that in the control pivot bracket.
Join them with the knurled shouldered screw (See
figure 21). Make sure that the gas control valve is
closed. Slide the control knob fully from top to
bottom and back to make sure that the slide and
pivot mechanisms move smoothly. Note that some
resistance should be felt when the slide knob
reaches the “burner fully on” position.
Fig. 21 Control bar & pivot bracket (Shown with “Adorn”
f
Fig. 18 “Visage” front casting top location
Fig. 19 “Adorn” Front casting bottom fixing
Fig. 20 “Visage” Front surround bottom fixing
f i r e - p a r t s . c o m