Valor 722AP Installation And Owner'S Manual Download Page 1

Model 722AN - for Natural Gas

Model 722AP - for Propane Gas

GAS FIREPLACE

  

With 

ADORN 

or 

VISAGE 

Fire Front

This appliance is a domestic room heating appliance. It must not be used for any other purpose
such as drying clothes etc.

600A727/09

INSTALLATION

 AND OWNER’S

MANUAL

Please read this manual before
installing and operating.

-

 

Do not store or use gasoline or other flammable  vapors
and liquids in the vicinity of this or any other appliance.

-

 

WHAT TO DO IF YOU SMELL GAS

 

Do not try to light any appliance

 

Do not touch any electrical switch

 

Do not use any phone in your building.

 

Immediately call your gas supplier from a neighbor’s
phone. Follow the gas suppliers instructions.

 

If you cannot reach your gas supplier, call the fire
department.

- Installation and service must be performed by a qualified
installer, service agency or the gas supplier

WARNING: If the
information in these
instructions is not followed
exactly, a fire or explosion
may result causing property
damage, personal injury or
death.

f i r e - p a r t s . c o m

Summary of Contents for 722AP

Page 1: ...ity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supp...

Page 2: ...supply line installation 9 Convection box installation 10 Gas supply connection 11 Ceramic walls installation 11 Front control linkage installation 11 Ceramic coals installation 13 Operation checks 1...

Page 3: ...ity of the appliance after installation e g additional mantle etc make sure that the changes conform to the installation requirements in this manual Never attempt to burn paper or any other material i...

Page 4: ...d in the open position The appliance can be installed in the following constructions 4 1 Solid fuel Non combustible fireplaces As supplied this appliance can be installed as an inset in an existing so...

Page 5: ...E FROM BASE VISAGE FRONT 40 43 OF HEATER B ADORN FRONT 53 with appliance as supplied see page 4 for Valor Cast Suite application 43 with kit 721CRB Fig 2 Clearances to combustible materials in front...

Page 6: ...learance kit enclosure 5 SUPPLY GAS Model 722AN is for use only with natural gas Model 722AP is for use only with propane gas The supply pressure must be between the limits shown in section 3 of this...

Page 7: ...Canopy shield 3 Thread cutting screws for canopy shield 2 Machine screws for front surround fixing or Pack 2 Visage Fire Front contains 1 Fire front surround with sliding control 1 Fire front casting...

Page 8: ...e thermocouple tip see figure 7 If there are no sparks make the following checks a Check condition of battery and that it is correctly fitted b Check spark gap between electrode wire and thermocouple...

Page 9: ...t sulfur compounds 8 3 Unions in gas lines should be of ground joint type 8 4 The gas supply line must be sized and installed to provide a supply of gas sufficient to meet the maximum demand of the ap...

Page 10: ...few inches clear of the fireplace front to allow you to fix the vent connector to the top of the convection box 9 4 Pull the vent connector towards the front of the fireplace and locate the rear slot...

Page 11: ...wall surfaces visible Fit the wall stamped B at the right side and the wall stamped A at the left side Find out which arrangement the customer requires Explain that the customer can not alter the wall...

Page 12: ...y to align the bottom fixing holes with those in the convection box Fix the bottom of the casting surround to the convection box with two screws See figure 19 or 20 12 4 Align the hole near the bottom...

Page 13: ...cess in the burner plaques and touch the ceramic plaques See figure 22 13 2 Place the ceramic front coal in position in front of the base coal Make sure that the side legs of the front coal are fully...

Page 14: ...d the rear multiple coal It has a square hole underneath Place it centrally behind the front multiple coals The square hole must locate in the square peg in the base coal See figure 26 13 6 Place a si...

Page 15: ...justed Lower the casting so that it rests on the floor see figure 29 14 3 Check valve control and slide control for proper operation as described in the lighting instructions section further on in thi...

Page 16: ...ng the guard back Release the springs so that they locate behind the canopy See figure 30 15 2 Visage front Locate the two wires projecting from each side of the guard into the holes in the inner face...

Page 17: ...ire off and allow it to cool before attempting any cleaning Note that the fire will retain heat for some time after it has been turned off Metal parts Clean the metal parts with a slightly damp cloth...

Page 18: ...bel 2 Turn the gas valve control counterclockwise as far as it will go shut 3 Move the control slide knob up to Off 4 Wait five 5 minutes to clear out any gas then smell for gas including near the flo...

Page 19: ...mber It will be helpful if the appliance serial number can also be quoted This is on the chained rating plate visible when the ashpan cover is removed The repair parts are shown in the separate repair...

Page 20: ...20 Manufactured by HEATING BIRMINGHAM ENGLAND Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Ltd fire parts com...