Overview

The 720SWK-M Sidewall Co-Linear Terminal Kit allows 

approved Valor units listed above only to be vented 

using approved 3-inch flexible vent liners to penetrate 

an existing masonry solid-fuel burning fireplace and 

connect to 720SWK-M horizontal termination rather than 

a vertical termination at the top of the chimney.
Use of this kit requires the vent collar slider plate to be 

replaced with a vent slider plate having no restrictor 

(4001133), supplied with this kit except where more than 

10’-0” vertical vent run.

Kit Contents

• Sidewall 

terminal

•  Vent slider plate with NO restrictor 4001133

Sidewall terminal

Front

Vent slider plate with NO 

restrictor 4001133

Rear

12”

12”

8-1/2”

3”

intake

3”

exhaust

©2022, Miles Industries Ltd.

Kit content

This kit must be installed or serviced by a 

qualified installer, service agency or gas 

supplier. These instructions are to be used 

in conjunction with the main installation 

instructions for the above listed models.

720SWK-M Sidewall Co-Linear Terminal Kit

Use with Valor models G3 739M and 739V Fireplaces ONLY

INSTALLATION INSTRUCTIONS

720SWK-M

WARNING

If these instructions are not followed 

exactlly, a fire or explosion may result 

causing property damage, personal 

injury or loss of life.

Please leave this manual with the homeowner.

Summary of Contents for 720SWK-M

Page 1: ...nts Sidewall terminal Vent slider plate with NO restrictor 4001133 Sidewall terminal Front Vent slider plate with NO restrictor 4001133 Rear 12 12 8 1 2 3 intake 3 exhaust 2022 Miles Industries Ltd Kit content This kit must be installed or serviced by a qualified installer service agency or gas supplier These instructions are to be used in conjunction with the main installation instructions for th...

Page 2: ... restrictor see instructions below The 739MN MP and 739VN VP do not have restrictor plates behind the rear log as other 739 models do 1 Remove the existing vent slider plate having built in restrictor 2 Replace with a vent slider plate having no restrictor supplied in this kit If more than 10 0 vertical vent run vent plate with restrictor can remain in place Vent plate with restrictor Vent plate w...

Page 3: ...original solid fuel fireplace into which the gas fireplace is being installed Attach Warning Conversion Plate to Existing Fireplace label supplied loose with 739 heater Attach the This fireplace has been converted label to the existing fireplace using screws or other mechanical means and store any removed parts in back of the existing fireplace for future use Exterior view Note Limited overlap of ...

Page 4: ...rovided with the fireplace 1 2 Description Part Numbers 1 Sidewall termination 4004410 2 Vent slider assembly 4001133 Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver B C CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www valorfireplaces com Because our policy is one of constant development and improvement details may vary slightly from those given...

Page 5: ...al est de plus de 10 pieds Contenu du kit Sortie d évacuation murale Plaque d évent sans restricteur 4001133 Sortie murale colinéaire Contenu du kit Plaque d évent sans restricteur 4001133 Cette trousse doit être installée et entretenue par un installateur qualifié une agence de service certifiée ou un fournisseur de gaz Ces instructions doivent être utilisées conjointement avec les instructions d...

Page 6: ...ous Les foyers 739MN MP et 739VN VP n ont pas de plaques de restricteur derrière la paroi arrière comme d autres modèles 739 1 Enlevez la plaque d évent avec restricteur intégré 2 Remplacez la avec la plaque d évent sans restricteur fournie Si le parcours vertical d évacuation est de plus de 10 pieds la plaque d évent avec restricteur peut demeurer en place Plaque d évent avec restricteur intégré ...

Page 7: ...lement considérez l interférence possible que l installation d un ventilateur ou d un robinet de sûreté peuvent avoir avec la parcours de la conduite de gaz Portes de verre et pare étincelles existants Les portes de verre doivent être enlevées complètement avant d installer le foyer à gaz Manteaux de cheminée combustibles Les dégagements pour les manteaux de cheminée combustibles doivent être conf...

Page 8: ... sortie 5 Tirez soigneusement tout excès de conduits vers l intérieur de la cheminée en vous assurant que les conduits ne sont pas affaissés coincés ou déchirés 6 Raccordez les conduits aux buses du foyer à l aide de 3 vis par conduits ou colliers de serrage à engrenage Assurez vous que le conduit d évacuation est raccordé à la buse d évacuation 7 Continuez l installation du foyer tel qu indiqué d...

Reviews: