19
7. APPLIANCE PREPARATION
7.1 Window Removal
See figure 20.
•
Turn the top three spring loaded window bolts through 90
0
to release the window
from the firebox.
•
Remove the bottom three spring-loaded window bolts.
•
Detach the chain from the top right corner of the window.
•
Carefully lift the window away. Keep the window and bolts in a safe place.
7.2 Ignition Spark Check
The pilot burner and electrode unit is at the left end of the burner.
Push in the lighting knob and turn counter-clockwise through the “IGN” position to
“PILOT”. A spark should flash across from the pilot electrode to the pilot burner shield.
See figure 21.
7.3 Rear Vent Outlet positioning
If installing with top vent outlet ignore this stage
See figure 22
1.
Remove the rear outlet cover plate and seal by unscrewing 12 screws.
Keep the seal and plate for fitting to the top.
2.
Remove the top outer vent collar and seal by unscrewing 12 screws.
3.
Remove the top inner vent collar and seal by unscrewing 8 screws.
4.
Locate the inner collar and seal inside the rear outlet opening. Secure the
inner collar with 8 screws.
5.
Fit the outer collar over inner collar. Loosely fit the 12 screws. Place the
Dura-vent adapter #817VAK or Valor terminal unit #551DVK over the
collars to check alignment. Tighten the 12 screws to secure the outer
collar.
6.
Fit the cover plate and seal (Removed from the rear) to the top vent
opening with 12 screws.
7.4 # 817VAK Pipe Adapter Fitting
If installing flat on wall with Valor terminal unit #551DVK ignore this
stage.
See figure 23.
1.
Fit the Dura-vent adapter #817VAK over the appliance vent collars
pushing on firmly.
2.
For rear vent outlet connection, align the adapter so that the seam on
horizontal Dura-vent pipes is not at the bottom – Check by temporarily
fitting a Dura-vent pipe.
3.
Drill through the adapter outer tube and appliance outer collar for #6
screws. See figure 40.
Make sure that the drill does not penetrate the
inner tubes.
4.
Secure the adapter to the outer collar with two #6 thread cutting screws
supplied.
Figure 21 Ignition spark check
Figure 20 Window removal
Figure 22
Summary of Contents for 534XAP
Page 18: ...18...