26
2 x 3”
liners
530
engine
Co-linear Vent Installations
1. The size of the
replace cavity required to insert the 530 engine varies with the
style of front trim chosen. Refer to the front trim installation manual for required
dimensions.
2. Place the appliance (
tted with the co-linear adapter) near the
replace opening but
allow space for manipulating the chimney liners on to the appliance.
3. Drop the 3-inch diameter
exible liners into the chimney from outside.
4. Fit the liners to the co-linear adapter paying attention to inlet and exhaust and move
the appliance to its proper position. Be aware of the minimum liner bend radius and
maximum liner horizontal run as shown on page 24 in this manual.
5. Fit the termination kit and
ashing if required to the exterior of the chimney.
6. Secure the appliance to the
oor or wall if necessary.
Vertical Termination Installations
Appliance Preparation
Burner Module Removal
It may be desirable to remove the burner module to gain access
for gas
tting, to install a fan kit, or to fasten the unit to the
oor or
plinth supplied with the zero clearance fronts.
Window Removal
1. Release the top of the window by pulling forward and rotating
outwards the two bars at the top corners.
2. Unscrew the two spring-loaded bolts securing the bottom of the
window.
3. Carefully lift the window. Keep the window and bolts in a safe
place.
4. Remove the packaged ceramic (Bricks/Logs/Coals/Rocks) from
rebox.
See venting accessories list on pages 40–41 for allowable components.
QUALIFIED
INSTALLER
Summary of Contents for 530ILN
Page 46: ......