MAINTENANCE

Battery replacement 

(See fig 11).

This appliance requires 9V PP3 Ever Ready Silver Seal (or equivalent)
battery.
To replace the battery remove the bottom front cover casting.
Fit the new battery firmly to the connections on the generator, the
positive battery terminal (+) being to the right as you insert. The guide
plate will help to locate the battery.

Regular maintenance

In order to achieve and maintain high levels of personal safety and performance
efficiency, it is essential that the opening at the back of the fire and the flue are kept clear
of any form of obstruction. It is possible that deposits of mortar or soot could fall and
accumulate causing the flue to be blocked or restricted and so preventing proper
clearance of dangerous exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant’s premises checked for safety at least every
twelve months by a competent person (In the U.K, a CORGI registered installer).
We recommend that all gas appliances and their flues, wherever situated, are checked
annually.

Servicing

 

In the United Kingdom servicing can be carried out either by a Valor Service

engineer or a CORGI registered installer.

 

If you require your fire to be serviced, please contact 

Valor Service

 on 

0121 386

6203

 and quote the following details;

a) - 

 

model name and number.

b) - 

 

appliance serial no. (To be found on a chained plate below the burner and behind

the bottom front cover)

 

If you wish to replace any of the owner replaceable parts listed below, please contact

Valor Sales 

on 

0121 386 6260

 for your nearest stockist of these parts. When ordering

please quote the part number shown below.

 

From the Republic of Ireland call 

0044 121 373 8111 

for all enquiries.

Description

Part No

Rear wall

545999

Front base coal halves

546009

Rear base coal

563359

Pack of  7 top coals

563369

Right side wall

546039

Left side wall

546049

When fitting replacement parts, follow the instructions contained in this guide. It is
important that only Valor approved parts are used for maximum safety

.

 

 Fig. 11. Battery fitting

Summary of Contents for 4191

Page 1: ...o n Front O W N E R G U I D E This Owner Guide is intended to help you care for your Valor gas fire Please read carefully before using your gas fire and keep for future reference This Owner Guide give...

Page 2: ...BACK COVER Page Safety _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Major Dimensions_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 Gas Consumption_ _ _ __ _ _...

Page 3: ...the fire Never add any extra coals above the number stated in these instructions This could cause a safety hazard 7 It should be appreciated that although this appliance conforms to all the applicabl...

Page 4: ...at the low setting of 4 3 kW Gross To calculate the running cost of this fire multiply the gas consumption gas input by the cost of gas which you will find on your gas bill GAS X COST RUNNING CONSUMPT...

Page 5: ...r in the instructions 2 Keep the button at the ignition position for a further ten seconds This will prevent the flame sensing device from shutting off the gas while its probe warms up as explained ab...

Page 6: ...away from your face so that you avoid inhaling the dust We do not recommend the use of a normal domestic vacuum cleaner which may blow dust back into the air We suggest that you remove the coals in t...

Page 7: ...oose coals as follows The smooth surfaces of the coals should be at the bottom and back 5 1 Select the two largest coals Place them in the central two valleys of the front coal See figure 8 5 2 Place...

Page 8: ...by a competent person In the U K a CORGI registered installer We recommend that all gas appliances and their flues wherever situated are checked annually Servicing In the United Kingdom servicing can...

Page 9: ...0345 626341 To report faults or arrange for your fire to be serviced VALOR SERVICE 0121 386 6203 To order spares or for sales information VALOR SALES 0121 386 6260 CALLERS IN THE REPUBLIC OF IRELAND C...

Page 10: ...ds Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our ga...

Reviews: