background image

7

3.

Place the rear base coal in the burner compartment behind the front coal. Its

rear face should touch the rear ceramic wall (See figure 6).

4.

The ceramic side walls are marked at the rear

bottom corners “L” (Left side) & “R” (Right side). Place
the side walls against the sides of the fire box and in the
recesses at the sides of the base coals. The markings  “L”
& “R” should be at the at the back bottom corners and
facing to the centre of the back of the firebox (See figure
7).

5.

Install the 7 loose

coals as follows. The
smooth surfaces of the
coals should be at the
bottom and back.

5.1.

Select the two

largest coals Place them in
the central two valleys of
the front coal (See figure
8).

5.2.

Place two of the remaining coals in the two

outer valleys of the front coal (One each side of the
large coals) (See figure 9). Place the left side coal so
that you will be able to see the pilot flame below the
coal.

5.3  

Place the three remaining coals behind and approximately midway between each

of the coals in the front row (See figure 10).

            

 Fig. 10 Middle row of coals

           

 Fig. 9 Front row outer coals

             

 Fig. 8 Front row inner coals

      

 Fig. 7 Ceramic side walls position

      

 Fig. 6 Rear base coal position

Summary of Contents for 4191

Page 1: ...o n Front O W N E R G U I D E This Owner Guide is intended to help you care for your Valor gas fire Please read carefully before using your gas fire and keep for future reference This Owner Guide give...

Page 2: ...BACK COVER Page Safety _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Major Dimensions_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 Gas Consumption_ _ _ __ _ _...

Page 3: ...the fire Never add any extra coals above the number stated in these instructions This could cause a safety hazard 7 It should be appreciated that although this appliance conforms to all the applicabl...

Page 4: ...at the low setting of 4 3 kW Gross To calculate the running cost of this fire multiply the gas consumption gas input by the cost of gas which you will find on your gas bill GAS X COST RUNNING CONSUMPT...

Page 5: ...r in the instructions 2 Keep the button at the ignition position for a further ten seconds This will prevent the flame sensing device from shutting off the gas while its probe warms up as explained ab...

Page 6: ...away from your face so that you avoid inhaling the dust We do not recommend the use of a normal domestic vacuum cleaner which may blow dust back into the air We suggest that you remove the coals in t...

Page 7: ...oose coals as follows The smooth surfaces of the coals should be at the bottom and back 5 1 Select the two largest coals Place them in the central two valleys of the front coal See figure 8 5 2 Place...

Page 8: ...by a competent person In the U K a CORGI registered installer We recommend that all gas appliances and their flues wherever situated are checked annually Servicing In the United Kingdom servicing can...

Page 9: ...0345 626341 To report faults or arrange for your fire to be serviced VALOR SERVICE 0121 386 6203 To order spares or for sales information VALOR SALES 0121 386 6260 CALLERS IN THE REPUBLIC OF IRELAND C...

Page 10: ...ds Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our ga...