2
Wiring diagram
and label
Fan Unit
Fan Mounting Plate
ThermalSwitch
Power cable
Considerations
We highly recommend installing this fan (blower) kit to
the appliance before completing the installation of the
appliance otherwise the gas line must be disconnected
and the burner module removed from the fi rebox to
gain access to the blower area.
If installing this fan after the fi replace installation has
been completed, remove the following components
using the fi replace installation manual provided with the
fi replace for guidelines:
•
Trim side doors, trim plinth, window, fuel bed,
vermiculate base platform, middle platform supports
(front and back).
•
Disconnect the gas line from the appliance at the
appliance valve.
NOTE: Electrical wiring must be already installed
inside the appliance case to complete the fan
installation.
Test the fan
It may be desireable to test the fan operation before
reassembling the burner module and completeing the
fi replace installation.
To test the fan operation the thermal switch can
be temporarily bypassed by connecting the power
cord lead directly to the fan motor (see diagram).
Unplug the power cord from the receptacle before
bypassing the thermal switch.
Confi rm fan operation
and speed control (if used) with the thermal switch
bypassed then reconnect thermal switch.
Note:
If desireable, the thermal switch may be
left permanently bypassed and the fan controlled
exclusively by the wall switch or speed control.
Fan Kits Components
The complete 1595CFK kit contains the following:
•
Fan unit (motor and housing)
•
Fan mounting plate
•
Thermal switch
•
Power cable
•
Wiring diagram label
•
Sheet metal screws (2)
Sheet metal
screws (2)
Remove wire from
switch and connect
directly to motor for
testing