7
Ratings
Model
N
P
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
36,000
31,000
Input Minimum (Btu/h)
15,000
15,000
Manifold Pressure (in
w.c.)
3.6”
10.5”
Minimum Supply
Pressure (in w.c.)
5”
11”
Maximum Supply
Pressure (in w.c.)
10”
14”
Main Burner Injector
Marking
Cat #
82-1200
Cat #
92-360
Pilot Injector Marking
#62
#30
Min. Rate By-Pass Screw
#190
#125
*High Altitude Installations
I
nput ratings are shown in BTU per hour and are
certified without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confirm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Specifications
Approval & Codes
This appliance is certified to ANSI Z21.88b-2008 / CSA
2.33b-2008
Vented Gas Fireplace Heater
standard for
use in Canada and USA, and to CGA 2.17-91
High
Altitude Standard in Canada
. This appliance is for
direct vent installations.
This appliance complies with CGA P.4.1
Testing
method for measuring annual fireplace efficiencies
.
The installation must conform to local codes or, in the
absence of local codes, with the
National Fuel Gas
Code, ANSI Z223.1
or the
Natural Gas and Propane
Installation Code CAN/CGA-B149
. Only qualified
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA
70
or the
Canadian Electrical Code, CSA C22.1
.
Supply Gas
Heater engine 1200EAN is used with natural gas.
Heater engine 1200EAP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
The supply connection is 3/8 inch NPT female and
located on the left hand side of the firebox.
Conversion Kits
The 1200 Ventana is supplied as natural gas or
propane gas and is field convertible between fuels. See
instructions packaged with the conversion kit for further
information.
Electrical
The 1200 does not require an electrical power source
to operate as a heater. However, it requires electrical
power to operate its decorative hearth light.
X
Summary of Contents for 1200EAN
Page 40: ...40 Wiring Diagram...