3. APPLIANCE DATA, EFFICIENCY AND NO
x
3.1 General information.
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does
not
exist for this gas fire.
The appliance information label is located on a ‘swing out’ plate at the base of the
fire. On fires that are already installed this can be seen by removing the bottom front
cover of the fascia.
Page 9
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Gas
Natural (G20)
Inlet Pressure
20mbar
Input - Max. (Gross)
3.9kW (13,307 Btu/h)
Input - Min. (Gross)
2.0kW (6,824 Btu/h)
Input - Max. (Net)
3.51kW (11,976 Btu/h)
Input - Min. (Net)
1.80kW (6,142 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
Gas Connection
8mm pipe
Burner Injector
Cat 82 - 280
Pilot & Atmosphere Sensing Device
Copreci Ref. O.D.S 21100/234
Ignition
Piezo electric, integral to with gas tap
Aeration
See section 20.1
Figure 1.