9.2 Fitting the foam seal.
There is a length of self adhesive foam seal supplied with the fire. This will need to be
fitted to the rear of the convection box as shown in figure 13. Cut the foam seal to the
required lengths. Be careful not to stretch the seal when measuring. Remove the
protective backing from the foam seal and fit this to the rear of the convection box
flange (See figure 13).
9.3 The flue restrictor.
This appliance is fitted with a flue restrictor for use where the flue draught is
excessive. The flue restrictor can be adjusted from the front of the fire so there is no
need to remove the fire from the fireplace for adjustment to be made. Generally we
recommend the restrictor is set to its fully open position where a precast flue, metal
flue box or a flue liner is used, however, certain flues may work sufficiently to warrant
its use. There may however, be circumstances where the restrictor causes the fire to
fail the spillage test. In such cases the restrictor will have to be set to its fully open
position and a spillage check conducted again.
The restrictor is supplied in the fully open position and can be adjusted. To adjust the
restrictor, locate the central screw at the rear of the convected air outlet (See figure
14). Loosen the screw and with the screw driver still in the head of the screw, slide
the restrictor to the desired position. Secure the restrictor by tightening the screw.
Page 26
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 13.
Summary of Contents for 964
Page 7: ...1 IMAGE Page 7 Baxi Heating U K Limited 2010 INSTALLER GUIDE Blenheim fascia ...
Page 22: ...Page 22 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 8 Pack contents ...
Page 45: ...IMAGE Page 45 Baxi Heating U K Limited 2010 OWNER GUIDE Blenheim fascia ...
Page 57: ...Page 57 Baxi Heating U K Limited 2010 OWNER GUIDE ...