7. IGNITION CHECK
Before attempting to install, it is worth checking that
the electronic ignition system performs
satisfactorily.
Fit the control knob to the slider assembly using
two M4 x 7mm screws supplied (See figure 10)
Fit the battery to the ignition block located below
the burner tray at the left side (See figure 11). The
+ve and -ve terminal positions are marked on the
battery holder body.
Depress the slider control knob as far as it will
go. This should close the ignition circuit. Sparks
should be seen tracking from the electrode pin to
the pilot tip (See figure 12).
If there are no sparks make the following checks.
Check condition of battery and that it is correctly
located.
If the above is satisfactory, check the ignition
circuit and components - see the servicing and
parts replacement section in this guide.
Page 24
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 12.
Figure 11.
Figure 10.