This product uses fuel effect pieces and burner compartment walls containing
Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres.
Excessive exposure to these materials may cause irritation to eyes, skin and
respiratory tract. Consequently, it is important to take care when handling these
articles to ensure that the release of dust is kept to a minimum. To ensure that
the release of fibres from these RCF articles is kept to a minimum, during
installation and servicing we recommend that you use a HEPA filtered vacuum
to remove any dust and soot accumulated in and around the fire before and
after working on the fire. When replacing these articles we recommend that the
replaced items are not broken up, but are sealed within a heavy duty polythene
bag, clearly labelled as RCF waste. RCF waste is classed as a stable, non-
reactive hazardous waste and may be disposed at a landfill licensed to accept
such waste. Protective clothing is not required when handling these articles,
but we recommend you follow the normal hygiene rules of not smoking, eating
or drinking in the work area and always wash your hands before eating or
drinking. This appliance does not contain any component manufactured from
asbestos or asbestos related products.
4. GENERAL INSTALLATION REQUIREMENTS
4.1
The installation must be in accordance with these instructions.
For the user’s protection, in the United Kingdom it is the law that all gas appliances
are installed by competent persons in accordance with the current edition of the Gas
Safety (Installation and Use) Regulations. Failure to install the appliance correctly
could lead to prosecution. CORGI requires its members to work to recognised
standards.
In the United Kingdom the installation must also be in accordance with:
All the relevant parts of local regulations.
All relevant codes of practice.
The relevant parts of the current editions of the following British Standards:-
BS EN 1856 Part 1
Chimneys - Requirements for metal chimneys.
BS 715
Specification for metal flue boxes for gas-fired appliances not
exceeding 20kW
BS EN 1858
Chimneys - Components - Concrete flue blocks
BS EN 1806
Chimneys - Clay / ceramic flue blocks
BS EN 1856 Part 1
Chimneys - Requirements for metal chimneys
BS 5440 Part 1
Installation of flues
BS 5440 Part 2
Installation and maintenance of flues and ventilation for gas
appliances of rated input not exceeding 70 kW net (1st, 2nd
and 3rd family gases).
BS 6461 Part 1
Masonry chimney & flues - Installation
BS 1251
Fireplace components
BS 5871 Part 2
Installation - Inset LFE gas fires
BS 6891
Gas pipework installation
©
Baxi Heating U.K. Limited 2008.
Page 8
INSTALLER GUIDE
Summary of Contents for 761