Pa ge 1 8
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
6. IGNITION CHECK
Before attempting to install, it is worth checking that
the ignition system performs satisfactorily.
Set the right hand control knob to the
‘OFF’
position.
!
Push in the right hand control knob and turn
anticlockwise through the ignition position marked
and up to the pilot position marked
. A
spark should flash across from the electrode pin to
the pilot tip. If there is no spark, check that the
spark gap is as shown in figure 7. If there is no
spark check the following: -
!
Ensure that the electrode lead is connected to
the terminal at the base of the electrode.
!
If the above is correct, check for damage to the
electrode lead.
7. GAS SUPPLY CONNECTION
A nut and olive are provided for an 8mm pipe inlet connection to the inlet ‘T’
connector at the bottom front of the appliance. The inlet ‘T’ connector can be rotated
to allow a connection from any direction. The inlet ‘T’ connector includes a valve for
isolating the gas supply and a pressure test point.
The supply pipe must be rigid material. Flexible pipe must not be used.
Concealed Supply Pipe Connection.
If a concealed connection from inside the fireplace is required then
,
before the
appliance is fitted into the fireplace
it will be necessary to extend the supply line so
that it will project through the hole in the back of the hotbox and run to the inlet ‘T’
connector at the front. The pipe run from the supply line up to the rear opening in the
hotbox must be kept away from the area which will be taken by the hotbox when it is
installed. Note that the centre of the appliance inlet ‘T’ connector is 25mm above the
fireplace floor. The inlet ‘T’ connector should be fitted to the supply pipe at this stage.
Figure 7. Ignition operation